Study on the Influencing Factors of Hot Spot Temperature of Oil-immersed Distribution Transformer Windings

The integration of distributed power and seasonal load fluctuations worsens three-phase imbalance, raising the risk of transformer winding overheating and possible failure. This paper uses 3D finite element simulation and experimental validation to study the effects of three-phase current imbalance, ambient temperature, insulation thickness, and thermal conductivity on the temperature of hot spot in transformers. It is shown that the hot spot temperature is directly affected by the average copper loss rate and the single-phase maximum current. Ambient temperature has a greater effect on the hot spot temperature of transformers with lower average copper loss rates and with windings with lower load factors. The higher the equivalent thermal conductivity of the windings and the thickness of the thin layer, the higher the hot spot temperature of the transformer, which is more pronounced on transformers and windings with higher average copper loss rates and higher load rates.

Authors

Institutions

Publication Details

Published
2025-04-11
DOI
https://doi.org/10.1109/pssgt64932.2025.11033850
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Influencing Factors of Hot Spot Temperature of Oil-immersed Distribution Transformer Windings

Yu Luo, You Zhou, Shi Mo, Lei Wang et al.
Power Transformer Diagnostics and Insulation
article

Study on the Influencing Factors of Hot Spot Temperature of Oil-immersed Distribution Transformer Windings

Yu Luo, You Zhou, Shi Mo, Lei Wang, Xiaoxuan Lin, Kehan Luo
article en

Abstract

The integration of distributed power and seasonal load fluctuations worsens three-phase imbalance, raising the risk of transformer winding overheating and possible failure. This paper uses 3D finite element simulation and experimental validation to study the effects of three-phase current imbalance, ambient temperature, insulation thickness, and thermal conductivity on the temperature of hot spot in transformers. It is shown that the hot spot temperature is directly affected by the average copper loss rate and the single-phase maximum current. Ambient temperature has a greater effect on the hot spot temperature of transformers with lower average copper loss rates and with windings with lower load factors. The higher the equivalent thermal conductivity of the windings and the thickness of the thin layer, the higher the hot spot temperature of the transformer, which is more pronounced on transformers and windings with higher average copper loss rates and higher load rates.

Changsha University of Science and Technology (CN), China Southern Power Grid (China) (CN)
China Southern Power Grid
Affordable and clean energy
Openalex Percentile: Top 88%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on the Influencing Factors of Hot Spot Temperature of Oil-immersed Distribution Transformer Windings — Yu Luo, You Zhou, et al. · (2025) | TGRS Research Map | TGRS