Zero-Sequence Component Blocking for Single-Phase Ground Fault in Transformerless SOP Flexible Interconnected System

With the rapid development of flexible interconnected distribution networks, the disadvantage of large site area for transformer in flexible interconnected systems is becoming increasingly prominent in practical applications. To deal with this problem, the transformerless SOP flexible interconnection system is proposed, the characteristics of zero sequence components on the fault free side when a single-phase grounding fault occurs in this system and the universal zero sequence interlocking strategy are analyzed. Simulation based on PSCAD shows that when different types and grounding methods of converters are put into this strategy, the zero sequence components on the fault free side are reduced to an ideal state

Authors

Institutions

Publication Details

Published
2025-04-11
DOI
https://doi.org/10.1109/pssgt64932.2025.11034232
Citations
1
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Zero-Sequence Component Blocking for Single-Phase Ground Fault in Transformerless SOP Flexible Interconnected System

Zhongxue Chang, Guobing Song, Heming Zhang
1 citations
Electric Power Systems and Control
0.73
article

Zero-Sequence Component Blocking for Single-Phase Ground Fault in Transformerless SOP Flexible Interconnected System

Zhongxue Chang, Guobing Song, Heming Zhang
article en
1 citations

Abstract

With the rapid development of flexible interconnected distribution networks, the disadvantage of large site area for transformer in flexible interconnected systems is becoming increasingly prominent in practical applications. To deal with this problem, the transformerless SOP flexible interconnection system is proposed, the characteristics of zero sequence components on the fault free side when a single-phase grounding fault occurs in this system and the universal zero sequence interlocking strategy are analyzed. Simulation based on PSCAD shows that when different types and grounding methods of converters are put into this strategy, the zero sequence components on the fault free side are reduced to an ideal state

Xi'an Jiaotong University (CN)
Research and Development
Climate action
Openalex Percentile: Top 27%
Electric Power Systems and Control
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.