Physical model of serum supplemented medium flow in organ-on-a-chip systems

Creating a physiologically relevant shear stress in organ-on-a-chip (OOC) devices requires careful tailoring of microfluidic flow parameters. Currently, it is fairly common to use a simple approximation assuming constant viscosity, even for serum-based media. Here, we show that a popular nutrient solution (Dulbecco's Modified Eagle Medium supplemented with Fetal Bovine Serum) requires a more complex treatment (i.e., is a non-Newtonian fluid), with observed shear stress values significantly greater than reported in literature. We measure the rheology of the solutions and combine it with a 3-dimensional flow field measurement to derive shear stress at the channel surface. We verify the experiments with numerical simulations, finding good agreement and deriving flow properties. Finally, we provide relevant expressions for the shear stress approximation, suitable for development of OOC devices with various geometries.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-06-17
DOI
https://doi.org/10.1371/journal.pone.0322069
Citations
1
Primary Topic
3D Printing in Biomedical Research
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physical model of serum supplemented medium flow in organ-on-a-chip systems

Guntars Kitenbergs, Jānis Cı̄murs, Una Riekstiņa, Ivars Driķis et al.
1 citations
PLoS ONE
3D Printing in Biomedical Research
0.67
article

Physical model of serum supplemented medium flow in organ-on-a-chip systems

Guntars Kitenbergs, Jānis Cı̄murs, Una Riekstiņa, Ivars Driķis, Karīna Goluba, Kaspars Jēkabsons, Vadims Parfejevs, Viesturs Šints, Gatis Mozoļevskis, Roberts Rimša, Mihails Birjukovs
article en
1 citations

Abstract

Creating a physiologically relevant shear stress in organ-on-a-chip (OOC) devices requires careful tailoring of microfluidic flow parameters. Currently, it is fairly common to use a simple approximation assuming constant viscosity, even for serum-based media. Here, we show that a popular nutrient solution (Dulbecco's Modified Eagle Medium supplemented with Fetal Bovine Serum) requires a more complex treatment (i.e., is a non-Newtonian fluid), with observed shear stress values significantly greater than reported in literature. We measure the rheology of the solutions and combine it with a 3-dimensional flow field measurement to derive shear stress at the channel surface. We verify the experiments with numerical simulations, finding good agreement and deriving flow properties. Finally, we provide relevant expressions for the shear stress approximation, suitable for development of OOC devices with various geometries.

PLoS ONEVol. 20(6)
University of Latvia (LV)
Clean water and sanitation
Openalex Percentile: Top 30%
3D Printing in Biomedical Research
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.