Tri-axial reaction forces (TRF), which support body mass and provide dynamic propulsion, are critical to improve motion stability, gait transitions, and energy efficiency in legged motions of both humans and robots. The accurate and robust sensing of TRF presents significant challenges due to the cyclic and high-impact loads. Existing commercial sensors with rigid encapsulation have a heavy weight and poor wearability, while flexible sensors with conformal capability are susceptible to damage under cyclic impacts due to complex structure and stress concentration between flexible and hard interfaces. This article proposes a flexible magnetoelastic sensing method that couples three-dimensional elastomer deformations with magnetic flux intensities to capture tri-axial load distributions. The locally-stiffened design mitigates stress concentration at the interfaces among soft elastomer, flexible substrate, and rigid chips. The plantar load sensing array is developed to measure loads up to 116, 113, and 433 kPa in the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x-</i>, <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y-</i>, and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">z-</i>axes, respectively, with durability validated by the 150 000-cycle compression test and 9-month clinical gait monitoring. The proposed method is illustrated with an immediate application to gait pattern identification, and it is anticipated to contribute to tri-axial force sensing in various scenarios, including but not limited to rehabilitation gait monitoring, legged robot navigation, and human–robot interaction.

Authors

Institutions

Publication Details

Journal
IEEE/ASME Transactions on Mechatronics
Published
2025-06-17
DOI
https://doi.org/10.1109/tmech.2025.3574948
Citations
2
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
1.91

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Durable and Flexible Magnetoelastic Sensing for Plantar Distributions of Normal and Shear Loads

Zijie Liu, Yuchao Liu, Xuan Wu, Jiajie Guo et al.
2 citations
IEEE/ASME Transactions on Mechatronics
Structural Health Monitoring Techniques
1.91
article

Durable and Flexible Magnetoelastic Sensing for Plantar Distributions of Normal and Shear Loads

Zijie Liu, Yuchao Liu, Xuan Wu, Jiajie Guo, Shabei Xu, Zhuo Li, Lei Li, Chuxuan Guo, Weipeng Li, Yibin Chen, Xiang Luo
article en
2 citations

Abstract

Tri-axial reaction forces (TRF), which support body mass and provide dynamic propulsion, are critical to improve motion stability, gait transitions, and energy efficiency in legged motions of both humans and robots. The accurate and robust sensing of TRF presents significant challenges due to the cyclic and high-impact loads. Existing commercial sensors with rigid encapsulation have a heavy weight and poor wearability, while flexible sensors with conformal capability are susceptible to damage under cyclic impacts due to complex structure and stress concentration between flexible and hard interfaces. This article proposes a flexible magnetoelastic sensing method that couples three-dimensional elastomer deformations with magnetic flux intensities to capture tri-axial load distributions. The locally-stiffened design mitigates stress concentration at the interfaces among soft elastomer, flexible substrate, and rigid chips. The plantar load sensing array is developed to measure loads up to 116, 113, and 433 kPa in the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x-</i>, <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y-</i>, and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">z-</i>axes, respectively, with durability validated by the 150 000-cycle compression test and 9-month clinical gait monitoring. The proposed method is illustrated with an immediate application to gait pattern identification, and it is anticipated to contribute to tri-axial force sensing in various scenarios, including but not limited to rehabilitation gait monitoring, legged robot navigation, and human–robot interaction.

IEEE/ASME Transactions on MechatronicsVol. 30(6)
Fudan University (CN), China Academy of Information and Communications Technology (CN), Tongji Hospital (CN), Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 15%
Structural Health Monitoring Techniques
1.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.