Replacing Attention With Modality-Wise Convolution for Energy-Efficient PPG-Based Heart Rate Estimation Using Knowledge Distillation

Continuous monitoring of Hearth Rate (HR) based on photoplethysmography (PPG) sensors is an essential capability of nearly all wrist-worn devices. However, arm movements lead to the creation of Motion Artifacts (MA), affecting the accuracy of HR tracking using PPG sensors. This problem is commonly tackled by exploiting the recorded accelerometer data to correlate them with the PPG signal and eventually clean it. Thus, automatic fusion techniques based on Deep Learning (DL) algorithms have been proposed, but they are considered too large and complex to be deployed on wearable devices. The current work presents a novel and lightweight DL architecture, PULSE, improving sensor fusion by applying a multi-head cross-attention layer to the extracted temporal features. Moreover, we propose a relation-based knowledge distillation mechanism to pass PULSE's knowledge to a student network that uses modality-wise convolutions to replace the attention module and mimic the teacher's performance with 5× fewer parameters. The teacher and student are evaluated on two datasets: a) PPG-DaLiA the most extensive available dataset, with PULSE achieving close performance to the best state-of-the-art model, and b) WESAD with PULSE reducing the mean absolute error by 22.6%. The student model is further compressed using post-training quantization and deployed on two commercial-off-the-shelf microcontrollers, demonstrating its suitability for real-time execution, having a close-to-state-of-the-art MAE of 4.81 BPM (+0.40 BPM) on the PPG-DaLiA, but a 10.9× lower memory footprint of 37.9 kB, and consuming 45.9× lower energy (0.577 mJ).

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-06-17
DOI
https://doi.org/10.1109/jbhi.2025.3580474
Citations
2
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
2.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Replacing Attention With Modality-Wise Convolution for Energy-Efficient PPG-Based Heart Rate Estimation Using Knowledge Distillation

Alessio Burrello, Lazaros Toumanidis, Daniele Jahier Pagliari, Panagiotis Kasnesis
2 citations
IEEE Journal of Biomedical and Health Informatics
EEG and Brain-Computer Interfaces
2.86
article

Replacing Attention With Modality-Wise Convolution for Energy-Efficient PPG-Based Heart Rate Estimation Using Knowledge Distillation

Alessio Burrello, Lazaros Toumanidis, Daniele Jahier Pagliari, Panagiotis Kasnesis
article en
2 citations

Abstract

Continuous monitoring of Hearth Rate (HR) based on photoplethysmography (PPG) sensors is an essential capability of nearly all wrist-worn devices. However, arm movements lead to the creation of Motion Artifacts (MA), affecting the accuracy of HR tracking using PPG sensors. This problem is commonly tackled by exploiting the recorded accelerometer data to correlate them with the PPG signal and eventually clean it. Thus, automatic fusion techniques based on Deep Learning (DL) algorithms have been proposed, but they are considered too large and complex to be deployed on wearable devices. The current work presents a novel and lightweight DL architecture, PULSE, improving sensor fusion by applying a multi-head cross-attention layer to the extracted temporal features. Moreover, we propose a relation-based knowledge distillation mechanism to pass PULSE's knowledge to a student network that uses modality-wise convolutions to replace the attention module and mimic the teacher's performance with 5× fewer parameters. The teacher and student are evaluated on two datasets: a) PPG-DaLiA the most extensive available dataset, with PULSE achieving close performance to the best state-of-the-art model, and b) WESAD with PULSE reducing the mean absolute error by 22.6%. The student model is further compressed using post-training quantization and deployed on two commercial-off-the-shelf microcontrollers, demonstrating its suitability for real-time execution, having a close-to-state-of-the-art MAE of 4.81 BPM (+0.40 BPM) on the PPG-DaLiA, but a 10.9× lower memory footprint of 37.9 kB, and consuming 45.9× lower energy (0.577 mJ).

IEEE Journal of Biomedical and Health InformaticsVol. 30(1)
Politecnico di Torino (IT), Consolidated Contractors Company (Greece) (GR)
Affordable and clean energy
Openalex Percentile: Top 10%
EEG and Brain-Computer Interfaces
2.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.