Continuous Estimation of FES-Induced Neuromuscular Fatigue Using Mechanomyography Signals

Functional Electrical Stimulation (FES), a key therapy for improving extremity function (e.g., in post-stroke patients), is limited by rapid FES-induced muscle fatigue. Additionally, Electromyography (EMG) monitoring is significantly compromised by FES artifacts. Mechanomyography (MMG), directly immune to such electrical FES artifacts, offers a promising alternative for fatigue estimation; however, its quantitative use for closed-loop FES remains underdeveloped. This study validated an MMG-based FES fatigue assessment system, introducing a novel wearable sensor (pressure P_MMG, microphone M_MMG) and an MMG-driven Tibialis Anterior (TA) musculotendon model with an MMG-derived fatigue index. An isometric FES fatigue protocol was conducted on control ($N=15$) and post-stroke ($N=3$) participants, recording force and MMG signals. P_MMG Mean Value (MV) signals consistently decreased with fatigue, showing strong average Pearson correlations ($\bar{r}$) with force decline in both control ($\bar{r}=0.740$) and stroke ($\bar{r}=0.928$) groups ($p \leq 0.005$). Conversely, M_MMG signals exhibited inconsistent trends and weaker force correlations, largely due to non-monotonic behavior in many participants. The P_MMG MV-driven model accurately predicted force decline, achieving mean coefficients of determination ($R^{2}$) of 0.741 (control) and 0.774 (stroke), with strong prediction correlations ($\bar{r} > 0.87, p < 0.01$). Model predictions utilizing M_MMG signals were successful only for participant subsets with consistent signal trends. The pressure-based P_MMG sensor provided a robust, non-invasive FES-induced fatigue indicator. The P_MMG-driven model allows continuous estimation of force capacity decline, promising for closed-loop FES to optimize rehabilitation.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-06-17
DOI
https://doi.org/10.1109/jbhi.2025.3580560
Citations
1
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous Estimation of FES-Induced Neuromuscular Fatigue Using Mechanomyography Signals

Ravi Vaidyanathan, Weiguang Huo, Paul Bentley, Anthony M. J. Bull et al.
1 citations
IEEE Journal of Biomedical and Health Informatics
Muscle activation and electromyography studies
0.67
article

Continuous Estimation of FES-Induced Neuromuscular Fatigue Using Mechanomyography Signals

Ravi Vaidyanathan, Weiguang Huo, Paul Bentley, Anthony M. J. Bull, Zhenhua Yu, Zehao Liu
article en
1 citations

Abstract

Functional Electrical Stimulation (FES), a key therapy for improving extremity function (e.g., in post-stroke patients), is limited by rapid FES-induced muscle fatigue. Additionally, Electromyography (EMG) monitoring is significantly compromised by FES artifacts. Mechanomyography (MMG), directly immune to such electrical FES artifacts, offers a promising alternative for fatigue estimation; however, its quantitative use for closed-loop FES remains underdeveloped. This study validated an MMG-based FES fatigue assessment system, introducing a novel wearable sensor (pressure P_MMG, microphone M_MMG) and an MMG-driven Tibialis Anterior (TA) musculotendon model with an MMG-derived fatigue index. An isometric FES fatigue protocol was conducted on control ($N=15$) and post-stroke ($N=3$) participants, recording force and MMG signals. P_MMG Mean Value (MV) signals consistently decreased with fatigue, showing strong average Pearson correlations ($\bar{r}$) with force decline in both control ($\bar{r}=0.740$) and stroke ($\bar{r}=0.928$) groups ($p \leq 0.005$). Conversely, M_MMG signals exhibited inconsistent trends and weaker force correlations, largely due to non-monotonic behavior in many participants. The P_MMG MV-driven model accurately predicted force decline, achieving mean coefficients of determination ($R^{2}$) of 0.741 (control) and 0.774 (stroke), with strong prediction correlations ($\bar{r} > 0.87, p < 0.01$). Model predictions utilizing M_MMG signals were successful only for participant subsets with consistent signal trends. The pressure-based P_MMG sensor provided a robust, non-invasive FES-induced fatigue indicator. The P_MMG-driven model allows continuous estimation of force capacity decline, promising for closed-loop FES to optimize rehabilitation.

IEEE Journal of Biomedical and Health InformaticsVol. 29(11)
Nankai University (CN), Imperial College London (GB)
Openalex Percentile: Top 30%
Muscle activation and electromyography studies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.