Enhancing Ultrasound-Based Diagnosis of Unilateral Diaphragmatic Paralysis With a Visual Transformer-Based Model

This paper presents a novel methodology that combines a pre-trained Visual Transformer-Based Deep Model (ViT) with a custom denoising image filter for the diagnosis of Unilateral Diaphragmatic Paralysis (UDP) using Ultrasound (US) images. The ViT is employed to extract complex features from US images of 17 volunteers, capturing intricate patterns and details that are critical for accurate diagnosis. The extracted features are then fed into an ensemble learning model to determine the presence of UDP. The proposed framework achieves an average accuracy of 93.8% on a stratified 5-fold cross-validation, surpassing relevant state-of-the-art (SOTA) image classifiers. This high level of performance underscores the robustness and effectiveness of the framework, highlighting its potential as a prominent diagnostic tool in medical imaging.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-06-17
DOI
https://doi.org/10.1109/jbhi.2025.3580447
Primary Topic
Congenital Diaphragmatic Hernia Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Ultrasound-Based Diagnosis of Unilateral Diaphragmatic Paralysis With a Visual Transformer-Based Model

Konstantinos I. Tsamis, Alexandros Kalkanis, Dries Testelmans, Bertien Buyse et al.
IEEE Journal of Biomedical and Health Informatics
Congenital Diaphragmatic Hernia Studies
article

Enhancing Ultrasound-Based Diagnosis of Unilateral Diaphragmatic Paralysis With a Visual Transformer-Based Model

Konstantinos I. Tsamis, Alexandros Kalkanis, Dries Testelmans, Bertien Buyse, Yannis V. Simos, George Manis, Dimitrios Bakalis
article en

Abstract

This paper presents a novel methodology that combines a pre-trained Visual Transformer-Based Deep Model (ViT) with a custom denoising image filter for the diagnosis of Unilateral Diaphragmatic Paralysis (UDP) using Ultrasound (US) images. The ViT is employed to extract complex features from US images of 17 volunteers, capturing intricate patterns and details that are critical for accurate diagnosis. The extracted features are then fed into an ensemble learning model to determine the presence of UDP. The proposed framework achieves an average accuracy of 93.8% on a stratified 5-fold cross-validation, surpassing relevant state-of-the-art (SOTA) image classifiers. This high level of performance underscores the robustness and effectiveness of the framework, highlighting its potential as a prominent diagnostic tool in medical imaging.

IEEE Journal of Biomedical and Health InformaticsVol. 29(10)
University of Ioannina (GR), KU Leuven (BE)
Openalex Percentile: Top 76%
Congenital Diaphragmatic Hernia Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing Ultrasound-Based Diagnosis of Unilateral Diaphragmatic Paralysis With a Visual Transformer-Based Model — Konstantinos I. Tsamis, Alexandros Kalkanis, et al. · IEEE Journal of Biomedical and Health Informatics (2025) | TGRS Research Map | TGRS