Time-Domain Backup Protection for Converter Dominated Hybrid AC–DC Microgrids

This article presents a backup protection scheme for hybrid ac–dc microgrids. A time-domain technique is proposed to isolate the faulted dc and ac subgrids from the point of common coupling using ac and dc currents, respectively, in case the primary protection fails. Symmetrical component decomposition in a bipolar dc microgrid is used to obtain the mode-0 and mode-1 current at the terminal of the bidirectional interlink converter (BIC). The superimposed component of mode-1 current acts as the decisive discriminator between ac and dc subgrid faults. One cycle moving average of the phase currents at the BIC terminal identifies the ground faults in dc subgrids. Further, the pole-to-pole faults in the dc grids can be detected using two consecutive zero-crossing widths in the phase currents at the ac terminal. The proposed protection scheme is validated on a hybrid ac–dc microgrid, simulated using a real-time digital simulator and a digital signal processor in a hardware-in-loop scenario for different faults on either side of the microgrid.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Informatics
Published
2025-06-17
DOI
https://doi.org/10.1109/tii.2025.3574424
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-Domain Backup Protection for Converter Dominated Hybrid AC–DC Microgrids

Soumya R. Mohanty, Ambuj Pandey, Rabindra Mohanty
IEEE Transactions on Industrial Informatics
HVDC Systems and Fault Protection
article

Time-Domain Backup Protection for Converter Dominated Hybrid AC–DC Microgrids

Soumya R. Mohanty, Ambuj Pandey, Rabindra Mohanty
article en

Abstract

This article presents a backup protection scheme for hybrid ac–dc microgrids. A time-domain technique is proposed to isolate the faulted dc and ac subgrids from the point of common coupling using ac and dc currents, respectively, in case the primary protection fails. Symmetrical component decomposition in a bipolar dc microgrid is used to obtain the mode-0 and mode-1 current at the terminal of the bidirectional interlink converter (BIC). The superimposed component of mode-1 current acts as the decisive discriminator between ac and dc subgrid faults. One cycle moving average of the phase currents at the BIC terminal identifies the ground faults in dc subgrids. Further, the pole-to-pole faults in the dc grids can be detected using two consecutive zero-crossing widths in the phase currents at the ac terminal. The proposed protection scheme is validated on a hybrid ac–dc microgrid, simulated using a real-time digital simulator and a digital signal processor in a hardware-in-loop scenario for different faults on either side of the microgrid.

IEEE Transactions on Industrial InformaticsVol. 21(9)
Indian Institute of Technology BHU (IN), Indian Institute of Technology Delhi (IN), Banaras Hindu University (IN)
Affordable and clean energy
Openalex Percentile: Top 88%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.