Innovative Design and Fabrication of Monolithic Columns Inside Microchip Devices for Determination of Ni(II) Ions

An innovative system was developed by fabricating a polymer-based monolith as an effective cation-exchange column within a glass microchip, achieved through in situ polymerization of glycidyl methacrylate (GMA), acrylic acid (AAc), and acrylamide (AAm) via free radical polymerization. Epoxy rings on the monolith surface were subsequently sulfonated with Na2SO3 at 70°C to form (R-SO3Na) groups. The microchip was integrated with a modified HPLC system equipped with a 3-way sub-valve (25 μL), allowing for the reagent-injection of the imidazole-azo ligand MPDADPI to react with Ni(II) ions and form a colored complex at 513 nm within 30 seconds. The calibration curve followed Beer’s law over the range of 0.001–3.5 μg mL-¹ (R² = 0.9977). Limits of detection (LOD) and quantification (LOQ) were 0.87 and 2.87 ng mL-¹, respectively. The method was validated using atomic absorption spectrophotometry (AAS).An innovative system was developed by fabricating a polymer-based monolith as an effective cation-exchange column within a glass microchip, achieved through in situ polymerization of glycidyl methacrylate (GMA), acrylic acid (AAc), and acrylamide (AAm) via free radical polymerization. Epoxy rings on the monolith surface were subsequently sulfonated with Na2SO3 at 70°C to form (R-SO3Na) groups. The microchip was integrated with a modified HPLC system equipped with a 3-way sub-valve (25 μL), allowing for the reagent-injection of the imidazole-azo ligand MPDADPI to react with Ni(II) ions and form a colored complex at 513 nm within 30 seconds. The calibration curve followed Beer’s law over the range of 0.001–3.5 μg mL-¹ (R² = 0.9977). Limits of detection (LOD) and quantification (LOQ) were 0.87 and 2.87 ng mL-¹, respectively. The method was validated using atomic absorption spectrophotometry (AAS).

Authors

Publication Details

Journal
METHODS AND OBJECTS OF CHEMICAL ANALYSIS
Published
2025-01-01
DOI
https://doi.org/10.17721/moca.2025.128-134
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovative Design and Fabrication of Monolithic Columns Inside Microchip Devices for Determination of Ni(II) Ions

Srien Sithara Syed Nasser, Ahmed Ali Alkarimi, Dakhil Nassir Taha
4 links
METHODS AND OBJECTS OF CHEMICAL ANALYSIS
Analytical Chemistry and Sensors
article

Innovative Design and Fabrication of Monolithic Columns Inside Microchip Devices for Determination of Ni(II) Ions

Srien Sithara Syed Nasser, Ahmed Ali Alkarimi, Dakhil Nassir Taha
article en

Abstract

An innovative system was developed by fabricating a polymer-based monolith as an effective cation-exchange column within a glass microchip, achieved through in situ polymerization of glycidyl methacrylate (GMA), acrylic acid (AAc), and acrylamide (AAm) via free radical polymerization. Epoxy rings on the monolith surface were subsequently sulfonated with Na2SO3 at 70°C to form (R-SO3Na) groups. The microchip was integrated with a modified HPLC system equipped with a 3-way sub-valve (25 μL), allowing for the reagent-injection of the imidazole-azo ligand MPDADPI to react with Ni(II) ions and form a colored complex at 513 nm within 30 seconds. The calibration curve followed Beer’s law over the range of 0.001–3.5 μg mL-¹ (R² = 0.9977). Limits of detection (LOD) and quantification (LOQ) were 0.87 and 2.87 ng mL-¹, respectively. The method was validated using atomic absorption spectrophotometry (AAS).An innovative system was developed by fabricating a polymer-based monolith as an effective cation-exchange column within a glass microchip, achieved through in situ polymerization of glycidyl methacrylate (GMA), acrylic acid (AAc), and acrylamide (AAm) via free radical polymerization. Epoxy rings on the monolith surface were subsequently sulfonated with Na2SO3 at 70°C to form (R-SO3Na) groups. The microchip was integrated with a modified HPLC system equipped with a 3-way sub-valve (25 μL), allowing for the reagent-injection of the imidazole-azo ligand MPDADPI to react with Ni(II) ions and form a colored complex at 513 nm within 30 seconds. The calibration curve followed Beer’s law over the range of 0.001–3.5 μg mL-¹ (R² = 0.9977). Limits of detection (LOD) and quantification (LOQ) were 0.87 and 2.87 ng mL-¹, respectively. The method was validated using atomic absorption spectrophotometry (AAS).

METHODS AND OBJECTS OF CHEMICAL ANALYSISVol. 20(2)
Openalex Percentile: Top 82%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Innovative Design and Fabrication of Monolithic Columns Inside Microchip Devices for Determination of Ni(II) Ions — Srien Sithara Syed Nasser, Ahmed Ali Alkarimi, et al. · METHODS AND OBJECTS OF CHEMICAL ANALYSIS (2025) | TGRS Research Map | TGRS