A NOVEL DEVICE AND PRESSURE PROTOCOL FOR CONTROLLED NEGATIVE PRESSURE THERAPY IN DEEP PULMONARY INFEC-TIONS: DEVELOPMENT AND CLINICAL APPLICATION

Background: Vacuum-assisted closure (VAC) therapy has become a valuable tool in managing complex infections. However, its adaptation for intrathoracic use remains technically challenging due to risks of air leaks, cavity instability, and lack of standardized equipment for pulmonary applications. Objective: To describe a novel VAC drainage system and pressure protocol specifically designed for pulmonary abscess management and evaluate its clinical feasibility in diabetic pa-tients. Methods: An internally developed drainage system was constructed using a low-adhesion polyurethane sponge, modified thoracic catheter, and a programmable negative pres-sure regulator. The system delivers controlled suction at –80 mmHg, modulated through a pulsed cycle (5 minutes on, 2 minutes off). Clinical testing was performed in 12 patients with diabetic pulmonary abscess following surgical drainage. Parameters evaluated included tech-nical safety, drainage efficiency, cavity collapse rate, and postoperative complications. Results: All patients tolerated the device well with no cases of bronchopleural fistula or sponge dislocation. Average drainage duration was 5.8 ± 1.0 days, and cavity volume reduction >75% was achieved in 83.3% of cases by day 7. No infections related to the device were ob-served. The pulsed suction mode allowed stable pressure delivery without over-collapse or hemothorax. Conclusion: This customized VAC device and pressure protocol demonstrated clinical safety, technical stability, and high efficacy in managing pulmonary abscess in diabetic patients. It may serve as a prototype for broader use in thoracic VAC therapy and facilitate standardiza-tion in deep cavity infections.

Authors

Publication Details

Journal
International journal of modern medicine
Published
2025-05-01
DOI
https://doi.org/10.55640/ijmm-04-05-07
Primary Topic
MXene and MAX Phase Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A NOVEL DEVICE AND PRESSURE PROTOCOL FOR CONTROLLED NEGATIVE PRESSURE THERAPY IN DEEP PULMONARY INFEC-TIONS: DEVELOPMENT AND CLINICAL APPLICATION

Khamdamov Sh.A.
International journal of modern medicine
MXene and MAX Phase Materials
article

A NOVEL DEVICE AND PRESSURE PROTOCOL FOR CONTROLLED NEGATIVE PRESSURE THERAPY IN DEEP PULMONARY INFEC-TIONS: DEVELOPMENT AND CLINICAL APPLICATION

Khamdamov Sh.A.
article en

Abstract

Background: Vacuum-assisted closure (VAC) therapy has become a valuable tool in managing complex infections. However, its adaptation for intrathoracic use remains technically challenging due to risks of air leaks, cavity instability, and lack of standardized equipment for pulmonary applications. Objective: To describe a novel VAC drainage system and pressure protocol specifically designed for pulmonary abscess management and evaluate its clinical feasibility in diabetic pa-tients. Methods: An internally developed drainage system was constructed using a low-adhesion polyurethane sponge, modified thoracic catheter, and a programmable negative pres-sure regulator. The system delivers controlled suction at –80 mmHg, modulated through a pulsed cycle (5 minutes on, 2 minutes off). Clinical testing was performed in 12 patients with diabetic pulmonary abscess following surgical drainage. Parameters evaluated included tech-nical safety, drainage efficiency, cavity collapse rate, and postoperative complications. Results: All patients tolerated the device well with no cases of bronchopleural fistula or sponge dislocation. Average drainage duration was 5.8 ± 1.0 days, and cavity volume reduction >75% was achieved in 83.3% of cases by day 7. No infections related to the device were ob-served. The pulsed suction mode allowed stable pressure delivery without over-collapse or hemothorax. Conclusion: This customized VAC device and pressure protocol demonstrated clinical safety, technical stability, and high efficacy in managing pulmonary abscess in diabetic patients. It may serve as a prototype for broader use in thoracic VAC therapy and facilitate standardiza-tion in deep cavity infections.

International journal of modern medicineVol. 4(5)
Openalex Percentile: Top 90%
MXene and MAX Phase Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A NOVEL DEVICE AND PRESSURE PROTOCOL FOR CONTROLLED NEGATIVE PRESSURE THERAPY IN DEEP PULMONARY INFEC-TIONS: DEVELOPMENT AND CLINICAL APPLICATION — Khamdamov Sh.A. · International journal of modern medicine (2025) | TGRS Research Map | TGRS