Sensorless Compensation of DC-Link Current Pulsations in Energy Storage Systems

This study addresses the problem of DC-link current pulsations in four-wire AC/DC converters with energy storage operating under unbalanced load conditions. A sensorless compensation algorithm based on AC-side voltage and current measurements is proposed, eliminating the need for additional sensors. The algorithm incorporates a Second Order Generalized Integrator (SOGI) filter for accurate detection and compensation of the pulsating component. Experimental validation under severe asymmetry confirmed the method’s effectiveness. In case 1, the AC component of the DC-link current was reduced from 7 A to 1.4 A and, in case 2, from 3 A to 0.5 A. Corresponding FFT analysis showed a reduction in relative amplitude from 240% to 21.5% and from 264% to 22%, respectively. In an asymmetrical charging scenario (case 3), the AC component was reduced from 2.5 A to nearly 0 A, corresponding to a decrease from 42% to 4.9% in the FFT spectrum. These results demonstrate that the proposed method enables stable converter operation even under deep phase current imbalances, significantly improving energy storage reliability and utility grid performance.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-06-16
DOI
https://doi.org/10.3390/en18123153
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensorless Compensation of DC-Link Current Pulsations in Energy Storage Systems

Dariusz Zieliński, K. Gopakumar, Maciej Rudawski
Energies
Advanced DC-DC Converters
article

Sensorless Compensation of DC-Link Current Pulsations in Energy Storage Systems

Dariusz Zieliński, K. Gopakumar, Maciej Rudawski
article en

Abstract

This study addresses the problem of DC-link current pulsations in four-wire AC/DC converters with energy storage operating under unbalanced load conditions. A sensorless compensation algorithm based on AC-side voltage and current measurements is proposed, eliminating the need for additional sensors. The algorithm incorporates a Second Order Generalized Integrator (SOGI) filter for accurate detection and compensation of the pulsating component. Experimental validation under severe asymmetry confirmed the method’s effectiveness. In case 1, the AC component of the DC-link current was reduced from 7 A to 1.4 A and, in case 2, from 3 A to 0.5 A. Corresponding FFT analysis showed a reduction in relative amplitude from 240% to 21.5% and from 264% to 22%, respectively. In an asymmetrical charging scenario (case 3), the AC component was reduced from 2.5 A to nearly 0 A, corresponding to a decrease from 42% to 4.9% in the FFT spectrum. These results demonstrate that the proposed method enables stable converter operation even under deep phase current imbalances, significantly improving energy storage reliability and utility grid performance.

EnergiesVol. 18(12)
Indian Institute of Science Bangalore (IN), Lublin University of Technology (PL)
Openalex Percentile: Top 88%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Sensorless Compensation of DC-Link Current Pulsations in Energy Storage Systems — Dariusz Zieliński, K. Gopakumar, et al. · Energies (2025) | TGRS Research Map | TGRS