Differences between Radiation Dose Values under Wearing and Non-wearing Geometries of Personal Dosimeters during Sleep

With the return of residents after the Fukushima Daiichi Nuclear Power Station accident, the measurement results of radiation doses to residents can be used to assess the risk or safety of remaining in their homes. However, personal radiation doses vary depending on the behavior and residential environment of each subject, even for a group of subjects living in the same region at the same time. In past studies, subjects were required to wear a personal dosimeter on their chests outdoors, but they were not required to wear the device indoors. This study investigated the difference between the dose values indicated for the wearing and non-wearing geometries of personal dosimeters during sleep. In particular, an adult human phantom was used to compare the indicated dose values when personal dosimeters were placed on the chest (reproducing the wearing geometry) and near the head (reproducing the non-wearing geometry) in two houses with a high measured radiation dose. Furthermore, to understand the reason for the difference in the indicated dose values, the radiation dose rate during sleep was calculated using a radiation transport calculation code. The dose values for the wearing geometry were approximately 4% lower on the first floor and approximately 15% lower on the second floor than those for the non-wearing geometry. In addition, the radiation dose rates and radiation dose rate ratios (head/chest) differed by approximately 30% and 20%, respectively, depending on the distance from the nearest window (1 to 3 m).

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2025-06-16
DOI
https://doi.org/10.1097/hp.0000000000002001
Primary Topic
Radioactive contamination and transfer
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Differences between Radiation Dose Values under Wearing and Non-wearing Geometries of Personal Dosimeters during Sleep

Masatoshi Watanabe, Jun Hirouchi, Shogo Takahara
Health Physics
Radioactive contamination and transfer
article

Differences between Radiation Dose Values under Wearing and Non-wearing Geometries of Personal Dosimeters during Sleep

Masatoshi Watanabe, Jun Hirouchi, Shogo Takahara
article en

Abstract

With the return of residents after the Fukushima Daiichi Nuclear Power Station accident, the measurement results of radiation doses to residents can be used to assess the risk or safety of remaining in their homes. However, personal radiation doses vary depending on the behavior and residential environment of each subject, even for a group of subjects living in the same region at the same time. In past studies, subjects were required to wear a personal dosimeter on their chests outdoors, but they were not required to wear the device indoors. This study investigated the difference between the dose values indicated for the wearing and non-wearing geometries of personal dosimeters during sleep. In particular, an adult human phantom was used to compare the indicated dose values when personal dosimeters were placed on the chest (reproducing the wearing geometry) and near the head (reproducing the non-wearing geometry) in two houses with a high measured radiation dose. Furthermore, to understand the reason for the difference in the indicated dose values, the radiation dose rate during sleep was calculated using a radiation transport calculation code. The dose values for the wearing geometry were approximately 4% lower on the first floor and approximately 15% lower on the second floor than those for the non-wearing geometry. In addition, the radiation dose rates and radiation dose rate ratios (head/chest) differed by approximately 30% and 20%, respectively, depending on the distance from the nearest window (1 to 3 m).

Health PhysicsVol. 130(1)
Japan Atomic Energy Agency (JP)
Good health and well-being
Openalex Percentile: Top 87%
Radioactive contamination and transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Differences between Radiation Dose Values under Wearing and Non-wearing Geometries of Personal Dosimeters during Sleep — Masatoshi Watanabe, Jun Hirouchi, et al. · Health Physics (2025) | TGRS Research Map | TGRS