Clinical Validation of Commercial AI Software for the Detection of Incidental Vertebral Compression Fractures in CT Scans of the Chest and Abdomen

<b>Background/Objectives:</b> The objective of this study was to clinically validate the performance of the Nanox.AI HealthOST software in detecting incidental vertebral compression fractures (VCFs) on outpatient chest and abdomen CT scans using sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A secondary aim was to assess the rate of missed VCFs using initial radiologist reports. <b>Methods:</b> A retrospective analysis was performed on 590 outpatient CT scans. HealthOST, an artificial intelligence solution from Nanox.AI that allows for automated spine analysis using CT images was evaluated against a consensus ground truth established by two radiologists, including a senior musculoskeletal radiologist. Two vertebral body height reduction thresholds were tested: mild (>20%) and moderate (>25%). Original radiologist reports were reviewed to identify missed VCFs. <b>Results:</b> At the 20% threshold, the AI achieved a sensitivity of 92.0%, a specificity of 52.7%, a PPV of 16.5%, and an NPV of 98.5%. At the 25% threshold, sensitivity decreased to 78.0%, while specificity improved to 94.2%, with a PPV of 51.1% and an NPV of 98.2%. The AI identified 88% and 92% of fractures missed by radiologists at the 20% and 25% thresholds, respectively. <b>Conclusions:</b> The Nanox HealthOST AI solution demonstrates potential as an effective screening tool, with threshold selection adaptable to clinical needs with a secondary review by a radiologist that is advisable to ensure diagnostic accuracy. The study further indicates that radiologists often overlook VCFs in reporting non-indicated cases and that AI has a role in enhancing the detection and reporting of vertebral compression fractures in routine clinical practice.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-06-16
DOI
https://doi.org/10.3390/diagnostics15121530
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Validation of Commercial AI Software for the Detection of Incidental Vertebral Compression Fractures in CT Scans of the Chest and Abdomen

Dawn Pearce, Noah Kates Rose, Vinu Mathew, Earl R. Bogoch et al.
Diagnostics
Medical Imaging and Analysis
article

Clinical Validation of Commercial AI Software for the Detection of Incidental Vertebral Compression Fractures in CT Scans of the Chest and Abdomen

Dawn Pearce, Noah Kates Rose, Vinu Mathew, Earl R. Bogoch, Sidharth Saini
article en

Abstract

<b>Background/Objectives:</b> The objective of this study was to clinically validate the performance of the Nanox.AI HealthOST software in detecting incidental vertebral compression fractures (VCFs) on outpatient chest and abdomen CT scans using sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A secondary aim was to assess the rate of missed VCFs using initial radiologist reports. <b>Methods:</b> A retrospective analysis was performed on 590 outpatient CT scans. HealthOST, an artificial intelligence solution from Nanox.AI that allows for automated spine analysis using CT images was evaluated against a consensus ground truth established by two radiologists, including a senior musculoskeletal radiologist. Two vertebral body height reduction thresholds were tested: mild (>20%) and moderate (>25%). Original radiologist reports were reviewed to identify missed VCFs. <b>Results:</b> At the 20% threshold, the AI achieved a sensitivity of 92.0%, a specificity of 52.7%, a PPV of 16.5%, and an NPV of 98.5%. At the 25% threshold, sensitivity decreased to 78.0%, while specificity improved to 94.2%, with a PPV of 51.1% and an NPV of 98.2%. The AI identified 88% and 92% of fractures missed by radiologists at the 20% and 25% thresholds, respectively. <b>Conclusions:</b> The Nanox HealthOST AI solution demonstrates potential as an effective screening tool, with threshold selection adaptable to clinical needs with a secondary review by a radiologist that is advisable to ensure diagnostic accuracy. The study further indicates that radiologists often overlook VCFs in reporting non-indicated cases and that AI has a role in enhancing the detection and reporting of vertebral compression fractures in routine clinical practice.

DiagnosticsVol. 15(12)
St. Michael's Hospital (CA), University of Toronto (CA), Unity Health Toronto
Openalex Percentile: Top 87%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.