Extend <i>m/z</i> Range of External Ion Injection Into Ion Trap/TOFMS: SIMION Analysis

Ion trap usually serves as a TOF pusher region in ion trap time-of-flight mass spectrometer (IT/TOF), achieving benefits of high duty cycle, MS/MS capability, and high mass resolution. While a short ion trap rod length improves TOF resolution, it limits the mass range in coaxial IT/TOF. Through a computational study based on SIMION simulations, this work systematically investigates the influence of geometric parameters (trap rod length) and voltage parameters (bias DC voltage, end-cap electrode voltage) on the mass range of coaxial IT-TOF systems. By optimizing length of trap rod, over 90% injection efficiency was achieved within a m/z 400-1400 without sacrificing mass resolution. By implementing DC bias voltage adjustments for low-m/z ions and step voltage optimization on end-cap electrodes for high-m/z ions, the simulated mass range is extended to m/z 200-1400 with minimal mass discrimination. All above these findings are derived solely from simulation analysis.

Authors

Institutions

Publication Details

Journal
Journal of Mass Spectrometry
Published
2025-06-16
DOI
https://doi.org/10.1002/jms.5152
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extend m/z Range of External Ion Injection Into Ion Trap/TOFMS: SIMION Analysis

Lei Hua, Ping Chen, Lichuan Zhang, Haiyang Li et al.
Journal of Mass Spectrometry
Mass Spectrometry Techniques and Applications
article

Extend m/z Range of External Ion Injection Into Ion Trap/TOFMS: SIMION Analysis

Lei Hua, Ping Chen, Lichuan Zhang, Haiyang Li, Xuesong Zhang, Yuanyuan Xie, Yixue Cao, Chenxin Wu
article en

Abstract

Ion trap usually serves as a TOF pusher region in ion trap time-of-flight mass spectrometer (IT/TOF), achieving benefits of high duty cycle, MS/MS capability, and high mass resolution. While a short ion trap rod length improves TOF resolution, it limits the mass range in coaxial IT/TOF. Through a computational study based on SIMION simulations, this work systematically investigates the influence of geometric parameters (trap rod length) and voltage parameters (bias DC voltage, end-cap electrode voltage) on the mass range of coaxial IT-TOF systems. By optimizing length of trap rod, over 90% injection efficiency was achieved within a m/z 400-1400 without sacrificing mass resolution. By implementing DC bias voltage adjustments for low-m/z ions and step voltage optimization on end-cap electrodes for high-m/z ions, the simulated mass range is extended to m/z 200-1400 with minimal mass discrimination. All above these findings are derived solely from simulation analysis.

Journal of Mass SpectrometryVol. 60(7)
Dalian Institute of Chemical Physics (CN), Chinese Academy of Sciences (CN), Affiliated Zhongshan Hospital of Dalian University (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Chinese Academy of Sciences, National Key Research and Development Program of China, Dalian Science and Technology Innovation Fund
Reduced inequalities, Peace, Justice and strong institutions
Openalex Percentile: Top 87%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Extend <i>m/z</i> Range of External Ion Injection Into Ion Trap/TOFMS: SIMION Analysis — Lei Hua, Ping Chen, et al. · Journal of Mass Spectrometry (2025) | TGRS Research Map | TGRS