Accuracy of Dynamic Computer-Aided Implant Surgery for Biconometric Implant Positioning: A Retrospective Case Series Analysis

Background/Objectives: This retrospective study assessed the accuracy of implant positioning with dynamic computer-aided implant surgery (dCAIS) for Toronto Bridge fabrication, using a conometric prosthetic concept and a new intraoral splinting technique (CLIKSS). It compared discrepancies across various anatomical regions, bone qualities, and implant sites. Methods: This study involved 52 patients undergoing full-arch rehabilitation (17 in the mandible, 30 in the maxilla, and 5 in both), with 366 implants placed (125 in the mandible, 241 in the maxilla; 128 in post-extraction sites, and the remainder in healed sites). All implants were immediately loaded. Precision was assessed by measuring linear and three-dimensional (3D) angular deviations between planned and actual implant positions. Results: Measurement errors for apical linear and 3D deviations at the apex and entry point ranged from 0.24 ± 0.10 to 0.55 ± 0.57 mm, and angular deviations varied from 0.32 ± 0.65° to 0.35 ± 0.71°. Maxillary measurements were significantly higher at the entry, apical, and vertical levels, even when comparing anterior and posterior regions with the corresponding mandibular areas, while no differences were found in the angular deviation. Significant discrepancies were observed among different mandibular bone types. Maxillary post-extraction sites exhibited significantly greater deviations than mandibular sites in all parameters except angular deviation. No significant differences were found between healed and post-extraction sites within the same jaw. Conclusions: dCAIS improved implant placement accuracy, leading to predictable prosthetic outcomes, especially during parallel multi-implant insertions. This report introduced dCAIS for conometric/biconometric implant placement combined with the innovative CLIKSS technique as an effective intraoral split method for this prosthesis connection.

Authors

Institutions

Publication Details

Journal
Osteology
Published
2025-06-16
DOI
https://doi.org/10.3390/osteology5020018
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Dynamic Computer-Aided Implant Surgery for Biconometric Implant Positioning: A Retrospective Case Series Analysis

Adriano Piattelli, Carlos Fernando Mourão, Natalia Di Pietro, Massimo Del Fabbro et al.
Osteology
Dental Implant Techniques and Outcomes
article

Accuracy of Dynamic Computer-Aided Implant Surgery for Biconometric Implant Positioning: A Retrospective Case Series Analysis

Adriano Piattelli, Carlos Fernando Mourão, Natalia Di Pietro, Massimo Del Fabbro, Lorenzo Montesani, Giulia Marchioli, Luca Comuzzi, Tea Romasco, Francesco Inchingolo, Luca Signorini, Margherita Tumedei
article en

Abstract

Background/Objectives: This retrospective study assessed the accuracy of implant positioning with dynamic computer-aided implant surgery (dCAIS) for Toronto Bridge fabrication, using a conometric prosthetic concept and a new intraoral splinting technique (CLIKSS). It compared discrepancies across various anatomical regions, bone qualities, and implant sites. Methods: This study involved 52 patients undergoing full-arch rehabilitation (17 in the mandible, 30 in the maxilla, and 5 in both), with 366 implants placed (125 in the mandible, 241 in the maxilla; 128 in post-extraction sites, and the remainder in healed sites). All implants were immediately loaded. Precision was assessed by measuring linear and three-dimensional (3D) angular deviations between planned and actual implant positions. Results: Measurement errors for apical linear and 3D deviations at the apex and entry point ranged from 0.24 ± 0.10 to 0.55 ± 0.57 mm, and angular deviations varied from 0.32 ± 0.65° to 0.35 ± 0.71°. Maxillary measurements were significantly higher at the entry, apical, and vertical levels, even when comparing anterior and posterior regions with the corresponding mandibular areas, while no differences were found in the angular deviation. Significant discrepancies were observed among different mandibular bone types. Maxillary post-extraction sites exhibited significantly greater deviations than mandibular sites in all parameters except angular deviation. No significant differences were found between healed and post-extraction sites within the same jaw. Conclusions: dCAIS improved implant placement accuracy, leading to predictable prosthetic outcomes, especially during parallel multi-implant insertions. This report introduced dCAIS for conometric/biconometric implant placement combined with the innovative CLIKSS technique as an effective intraoral split method for this prosthesis connection.

OsteologyVol. 5(2)
Tufts University (US), University of Milan (IT), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), University of Chieti-Pescara (IT), Saint Camillus International University of Health and Medical Sciences (IT), University of Bari Aldo Moro (IT)
European Commission, Università degli Studi G. d'Annunzio Chieti - Pescara
Openalex Percentile: Top 81%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.