First surgical epicardial implantation of an extravascular implantable cardioverter-defibrillator lead for Ebstein anomaly in the United States

Ebstein anomaly (EA) is a rare congenital heart disease characterized by apical displacement of the tricuspid valve and subsequent right ventricular failure. Invasive interventions are often needed to treat these structural defects and the associated supraventricular and ventricular arrythmias that commonly occur. We present a patient with EA who received a bioprosthetic tricuspid valve implant and the first reported surgical epicardial implantation of an extravascular implantable cardioverter-defibrillator (EV-ICD; Aurora EV-ICD, Medtronic, Minneapolis, MN) lead in the United States.

Authors

Institutions

Publication Details

Journal
HeartRhythm Case Reports
Published
2025-06-16
DOI
https://doi.org/10.1016/j.hrcr.2025.06.014
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First surgical epicardial implantation of an extravascular implantable cardioverter-defibrillator lead for Ebstein anomaly in the United States

I. Niazi, Austin Deets, Vikram Nangia, Andrew Lin et al.
HeartRhythm Case Reports
Cardiac Arrhythmias and Treatments
article

First surgical epicardial implantation of an extravascular implantable cardioverter-defibrillator lead for Ebstein anomaly in the United States

I. Niazi, Austin Deets, Vikram Nangia, Andrew Lin, Daniel W. Nelson
article en

Abstract

Ebstein anomaly (EA) is a rare congenital heart disease characterized by apical displacement of the tricuspid valve and subsequent right ventricular failure. Invasive interventions are often needed to treat these structural defects and the associated supraventricular and ventricular arrythmias that commonly occur. We present a patient with EA who received a bioprosthetic tricuspid valve implant and the first reported surgical epicardial implantation of an extravascular implantable cardioverter-defibrillator (EV-ICD; Aurora EV-ICD, Medtronic, Minneapolis, MN) lead in the United States.

HeartRhythm Case ReportsVol. 11(9)
Aurora St. Luke's Medical Center (US)
Good health and well-being
Openalex Percentile: Top 76%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.