Simultaneous and sensitive determination of hydroquinone, catechol, and resorcinol with a palladium nanoparticles/poly(bromocresol green) modified glassy carbon electrode

In this study, catechol (CC), hydroquinone (HQ), and resorcinol (RC) - dihydroxybenzene isomers - were determined simultaneously using the composite surface. The proposed material was prepared <i>via</i> electrochemical polymerization of Bromocresol Green (BCG) followed by electrodeposition of palladium nanoparticles (Pd). The developed electrode was characterized using X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), Electrochemical Impedance Spectroscopy (EIS), and X-ray Energy Dispersive Spectroscopy (EDX) techniques. Electrochemical measurements were performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in pH 7 phosphate buffer solution. The Pd nanoparticle deposited polymerized BCG-modified glassy carbon electrode (Pd/Poly(BCG)/GCE) displayed enhanced current sensitivity for all three isomers compared to a bare GCE and Poly(BCG)/GCE. Thus, this was attributed to the synergistic effect of the improved active surface area of Poly(BCG) and the unique properties of Pd nanoparticles. Under optimized conditions, three well-separated oxidation peaks were achieved by DPV for HQ (19 mV), CC (130 mV), and RC (430 mV) at the Pd/Poly(BCG)/GCE during the simultaneous concentration change of the isomer mixture. The limit of detection values (S/N = 3) were found to be 89 nM, 74 nM, and 98 nM for HQ, CC, and RC, respectively. Thus, the high sensitivity, adequate reproducibility, good stability, and easy preparation of the Pd/Poly(BCG)/GCE surface made it a promising candidate for the determination of dihydroxybenzene isomers.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00511f
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous and sensitive determination of hydroquinone, catechol, and resorcinol with a palladium nanoparticles/poly(bromocresol green) modified glassy carbon electrode

Çağrı Ceylan Koçak
2 citations
Analytical Methods
Electrochemical sensors and biosensors
1.46
article

Simultaneous and sensitive determination of hydroquinone, catechol, and resorcinol with a palladium nanoparticles/poly(bromocresol green) modified glassy carbon electrode

Çağrı Ceylan Koçak
article en
2 citations

Abstract

In this study, catechol (CC), hydroquinone (HQ), and resorcinol (RC) - dihydroxybenzene isomers - were determined simultaneously using the composite surface. The proposed material was prepared <i>via</i> electrochemical polymerization of Bromocresol Green (BCG) followed by electrodeposition of palladium nanoparticles (Pd). The developed electrode was characterized using X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), Electrochemical Impedance Spectroscopy (EIS), and X-ray Energy Dispersive Spectroscopy (EDX) techniques. Electrochemical measurements were performed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in pH 7 phosphate buffer solution. The Pd nanoparticle deposited polymerized BCG-modified glassy carbon electrode (Pd/Poly(BCG)/GCE) displayed enhanced current sensitivity for all three isomers compared to a bare GCE and Poly(BCG)/GCE. Thus, this was attributed to the synergistic effect of the improved active surface area of Poly(BCG) and the unique properties of Pd nanoparticles. Under optimized conditions, three well-separated oxidation peaks were achieved by DPV for HQ (19 mV), CC (130 mV), and RC (430 mV) at the Pd/Poly(BCG)/GCE during the simultaneous concentration change of the isomer mixture. The limit of detection values (S/N = 3) were found to be 89 nM, 74 nM, and 98 nM for HQ, CC, and RC, respectively. Thus, the high sensitivity, adequate reproducibility, good stability, and easy preparation of the Pd/Poly(BCG)/GCE surface made it a promising candidate for the determination of dihydroxybenzene isomers.

Analytical MethodsVol. 17(27)
Dokuz Eylül University (TR)
Openalex Percentile: Top 17%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.