Physicochemical quality assessment of four asparaginases

L-Asparaginases (ASNases) are used for the treatment of acute lymphoblastic leukaemia. There are reports of quality problems for some therapeutic asparaginase products, especially those manufactured in middle-income countries. These products may exhibit decreased potency and/or decreased specific activity, or an elevated level of impurities such as host cell proteins. In this study, four different ASNase preparations that were not modified with polyethylene glycol were compared in detail regarding their quality: Spectrila®, Celginase™, Bionase®, and L-Aspase®. Samples were analyzed for protein content, impurities, and enzyme activity. Various chromatographic methods as well as mass spectrometry were used to assess purity and identity. Sample protein content, host cell protein, and enzyme activity showed some results that were out of target range for Celginase™ and Bionase®. These ASNase preparations also showed detectable levels of endotoxins. In gel electrophoresis, additional bands were found for Bionase®. Size exclusion chromatography showed increased high and low molecular weight species for Bionase® and L-Aspase®, and reversed-phase chromatography showed increased hydrophilic and hydrophobic species for Bionase®. In capillary zone electrophoresis, increased retention time for L-Aspase® and increased levels of charge variants for Bionase®, Celginase™, and L-Aspase® were seen. ASNase quality standards are crucial to ensure patient safety and product efficacy, as decreased potency and specific activity may affect efficacy in acute lymphoblastic leukaemia treatment, and increased impurities may affect immunogenicity. Out of four ASNase preparations tested in this study, only Spectrila® did not raise any quality concerns. The other three products exhibited quality problems, rendering them unsuitable according to established quality requirements defined in European and US guidelines for pharmaceutical development of parenteral drug products.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-06-16
DOI
https://doi.org/10.1371/journal.pone.0326106
Primary Topic
Acute Lymphoblastic Leukemia research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Physicochemical quality assessment of four asparaginases

R. Eichler, Christoph Radcke, Ulf Bergmann, Arndt Schnuchel et al.
1 links
PLoS ONE
Acute Lymphoblastic Leukemia research
article

Physicochemical quality assessment of four asparaginases

R. Eichler, Christoph Radcke, Ulf Bergmann, Arndt Schnuchel, Kerstin Pohl, Thorsten König, Vanessa Radtke
article en

Abstract

L-Asparaginases (ASNases) are used for the treatment of acute lymphoblastic leukaemia. There are reports of quality problems for some therapeutic asparaginase products, especially those manufactured in middle-income countries. These products may exhibit decreased potency and/or decreased specific activity, or an elevated level of impurities such as host cell proteins. In this study, four different ASNase preparations that were not modified with polyethylene glycol were compared in detail regarding their quality: Spectrila®, Celginase™, Bionase®, and L-Aspase®. Samples were analyzed for protein content, impurities, and enzyme activity. Various chromatographic methods as well as mass spectrometry were used to assess purity and identity. Sample protein content, host cell protein, and enzyme activity showed some results that were out of target range for Celginase™ and Bionase®. These ASNase preparations also showed detectable levels of endotoxins. In gel electrophoresis, additional bands were found for Bionase®. Size exclusion chromatography showed increased high and low molecular weight species for Bionase® and L-Aspase®, and reversed-phase chromatography showed increased hydrophilic and hydrophobic species for Bionase®. In capillary zone electrophoresis, increased retention time for L-Aspase® and increased levels of charge variants for Bionase®, Celginase™, and L-Aspase® were seen. ASNase quality standards are crucial to ensure patient safety and product efficacy, as decreased potency and specific activity may affect efficacy in acute lymphoblastic leukaemia treatment, and increased impurities may affect immunogenicity. Out of four ASNase preparations tested in this study, only Spectrila® did not raise any quality concerns. The other three products exhibited quality problems, rendering them unsuitable according to established quality requirements defined in European and US guidelines for pharmaceutical development of parenteral drug products.

PLoS ONEVol. 20(6)
Gesellschaft für Klinische Forschung (DE), Wacker Group (Germany) (DE), BioTeSys (Germany) (DE)
Medac
Reduced inequalities
Openalex Percentile: Top 81%
Acute Lymphoblastic Leukemia research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.