Shortening 7T MP2RAGE acquisition with compressed sensing: Evaluating quantitative accuracy and structural consistency

The aim of this study was to systematically evaluate the impact of compressed sensing (CS) on acquisition time, image quality, T1 mapping accuracy, and segmentation consistency in magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) at ultra-high fields (UHF). MP2RAGE sequences were acquired using the CS and parallel imaging (PI) technique, i.e., generalized autocalibrating partially parallel acquisitions (GRAPPA), with varying undersampling factors and samples per repetition time (TR). The acquisition time, quantitative accuracy of T1 mapping, and segmentation consistency across regions of interest (ROIs) were assessed. CS-MP2RAGE achieved a 61% reduction in acquisition time (< 3 min) compared with PI-MP2RAGE and maintained comparable image quality, segmentation accuracy, and T1-mapping fidelity. Higher undersampling factors effectively reduced scan duration but introduced segmentation volume mismatches of up to 20% and increased T1 values, despite the images appearing similar to PI-MP2RAGE. Reducing the number of samples per TR enhanced image quality, allowing for higher undersampling factors without a significant loss of fidelity, a finding consistent with previous studies. However, excessively low sampling densities destabilized reconstruction in complex ROIs. Our findings demonstrate that CS-MP2RAGE significantly reduces scan time while maintaining high image quality and quantitative accuracy, making it a viable alternative to GRAPPA in UHF applications. The interplay between undersampling factors and samples per TR is crucial for optimizing scan efficiency. Future studies should explore its application in clinical and research settings.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-06-16
DOI
https://doi.org/10.1371/journal.pone.0325783
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shortening 7T MP2RAGE acquisition with compressed sensing: Evaluating quantitative accuracy and structural consistency

Ikuhiro Kida
PLoS ONE
Advanced MRI Techniques and Applications
article

Shortening 7T MP2RAGE acquisition with compressed sensing: Evaluating quantitative accuracy and structural consistency

Ikuhiro Kida
article en

Abstract

The aim of this study was to systematically evaluate the impact of compressed sensing (CS) on acquisition time, image quality, T1 mapping accuracy, and segmentation consistency in magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) at ultra-high fields (UHF). MP2RAGE sequences were acquired using the CS and parallel imaging (PI) technique, i.e., generalized autocalibrating partially parallel acquisitions (GRAPPA), with varying undersampling factors and samples per repetition time (TR). The acquisition time, quantitative accuracy of T1 mapping, and segmentation consistency across regions of interest (ROIs) were assessed. CS-MP2RAGE achieved a 61% reduction in acquisition time (< 3 min) compared with PI-MP2RAGE and maintained comparable image quality, segmentation accuracy, and T1-mapping fidelity. Higher undersampling factors effectively reduced scan duration but introduced segmentation volume mismatches of up to 20% and increased T1 values, despite the images appearing similar to PI-MP2RAGE. Reducing the number of samples per TR enhanced image quality, allowing for higher undersampling factors without a significant loss of fidelity, a finding consistent with previous studies. However, excessively low sampling densities destabilized reconstruction in complex ROIs. Our findings demonstrate that CS-MP2RAGE significantly reduces scan time while maintaining high image quality and quantitative accuracy, making it a viable alternative to GRAPPA in UHF applications. The interplay between undersampling factors and samples per TR is crucial for optimizing scan efficiency. Future studies should explore its application in clinical and research settings.

PLoS ONEVol. 20(6)
National Institute of Information and Communications Technology (JP), The University of Osaka (JP)
Industry, innovation and infrastructure
Openalex Percentile: Top 79%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Shortening 7T MP2RAGE acquisition with compressed sensing: Evaluating quantitative accuracy and structural consistency — Ikuhiro Kida · PLoS ONE (2025) | TGRS Research Map | TGRS