Two-Stage Transformerless BI6-Topology-Based Microinverter
This paper proposes an application for the boost inverter 6 (BI6) topology as a microinverter, leveraging its capability of single-stage boost operation. A front-end DC-DC boost converter is added at the input side of the BI6 to increase the voltage-boosting gain and implement the maximum power point tracking (MPPT) technique. The BI6 is operated with a fixed boosting duty cycle, leaving two control variables in the system: the modulation index of the BI6, controlled by a current controller, and the duty cycle of the front-end boost converter, controlled by the MPPT controller. A MATLAB/Simulink simulation has been carried out to validate the proposed microinverter system.
Authors
- Hamza Makhamreh (ORCID: https://orcid.org/0000-0003-3980-0702)
- Ahmed Aljabi
Publication Details
- Published
- 2025-05-20
- DOI
- https://doi.org/10.1109/cpe-powereng63314.2025.11027272
- Citations
- 1
- Primary Topic
- Advanced DC-DC Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.73