Time-of-Flight Requirements to Mitigate Blurring Induced by Annihilation Photon Acollinearity

One of the limiting factors of spatial resolution in positron emission tomography (PET) imaging is annihilation photon acollinearity (APA). For whole-body PET scanners, APA induces a blur ranging from 1.7 to 2.2 mm FWHM. For long axial field-of-view (FOV) scanners, this range increases even more, depending on the maximum ring difference. It was previously shown that perfect time-of-flight (TOF) resolution sharpens the APA-induced blur by altering its expected Gaussian shape into a profile resembling a 1/r function, thereby reducing its contribution to spatial resolution loss. This suggests that the conventional theoretical limit of PET spatial resolution could be overcome if sufficient TOF resolution can be achieved. However, the requirements to achieve an observable gain in spatial resolution have yet to be explored. We propose an investigation of these requirements for whole-body and long axial FOV scanners, in terms of TOF resolution and count statistics. Using a fictive 81-cm diameter scanner with 2-mm wide detectors, we show that ultrafast TOF resolution-13 ps FWHM-enables an observable gain in spatial resolution for a range of count statistics. In addition, we show that lower TOF resolutions (i.e., higher TOF values of 27 or 67 ps) could mitigate APA for the oblique tubes of response of long axial FOV systems subjected to larger APA blurring. This last observation is of particular interest as it suggests that the nonstationary nature of spatial resolution in PET imaging can be further mitigated when such TOF precision is achieved.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2025-06-16
DOI
https://doi.org/10.1109/trpms.2025.3579209
Primary Topic
Advanced Optical Sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-of-Flight Requirements to Mitigate Blurring Induced by Annihilation Photon Acollinearity

Maxime Toussaint, Roger Lecomte, Francis Loignon-Houle, Jean-Pièrre Dussault
IEEE Transactions on Radiation and Plasma Medical Sciences
Advanced Optical Sensing Technologies
article

Time-of-Flight Requirements to Mitigate Blurring Induced by Annihilation Photon Acollinearity

Maxime Toussaint, Roger Lecomte, Francis Loignon-Houle, Jean-Pièrre Dussault
article en

Abstract

One of the limiting factors of spatial resolution in positron emission tomography (PET) imaging is annihilation photon acollinearity (APA). For whole-body PET scanners, APA induces a blur ranging from 1.7 to 2.2 mm FWHM. For long axial field-of-view (FOV) scanners, this range increases even more, depending on the maximum ring difference. It was previously shown that perfect time-of-flight (TOF) resolution sharpens the APA-induced blur by altering its expected Gaussian shape into a profile resembling a 1/r function, thereby reducing its contribution to spatial resolution loss. This suggests that the conventional theoretical limit of PET spatial resolution could be overcome if sufficient TOF resolution can be achieved. However, the requirements to achieve an observable gain in spatial resolution have yet to be explored. We propose an investigation of these requirements for whole-body and long axial FOV scanners, in terms of TOF resolution and count statistics. Using a fictive 81-cm diameter scanner with 2-mm wide detectors, we show that ultrafast TOF resolution-13 ps FWHM-enables an observable gain in spatial resolution for a range of count statistics. In addition, we show that lower TOF resolutions (i.e., higher TOF values of 27 or 67 ps) could mitigate APA for the oblique tubes of response of long axial FOV systems subjected to larger APA blurring. This last observation is of particular interest as it suggests that the nonstationary nature of spatial resolution in PET imaging can be further mitigated when such TOF precision is achieved.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 10(2)
Université de Sherbrooke (CA), Instituto de Instrumentación para Imagen Molecular (ES)
Québec Consortium for Drug Discovery, Natural Sciences and Engineering Research Council of Canada
Climate action
Openalex Percentile: Top 86%
Advanced Optical Sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.