High spectral energy density all-fiber nanosecond pulsed 1.7 μm light source for photoacoustic microscopy

We present a high spectral energy density all-fiber nanosecond pulsed 1.7 μm light source specifically designed for photoacoustic microscopy (PAM). The system targets the 1st overtone absorption of C-H bonds near 1720 nm within the near-infrared-III (NIR-III) window, where lipids exhibit strong optical absorption, and tissues benefit from reduced scattering and high permissible fluence. To achieve narrow-linewidth, high pulse energy, and high pulse repetition rate (PRR), we developed a master oscillator fiber amplifier architecture based on stimulated Raman scattering. A 1589.80 nm Raman pump and a custom-built narrow-linewidth Raman seed laser were employed to generate spectrally pure 1719.44 nm pulses (∼0.10 nm linewidth). The proposed light source delivers nanosecond pulses (∼5 ns) with high pulse energy (≥2.2 μJ) and tunable PRRs up to 300 kHz, resulting in a spectral energy density of approximately 22 μJ/nm-significantly higher than that of conventional 1.7 μm light sources. Performance of the NIR-PAM system was validated through resolution testing with a 1951 USAF target, demonstrating a spatial resolution of approximately 4.14 μm and an axial resolution of approximately 85.5 μm. Phantom imaging of CH<sub>2</sub>-rich polymer films and ex vivo lipid-rich biological tissues confirmed the system's high spatial fidelity and strong contrast for lipid-specific structures. This compact, stable, and spectrally refined light source with high spectral energy density can offer an effective solution for high-resolution, label-free molecular imaging and represents a promising platform for clinical photoacoustic imaging applications involving lipid detection and metabolic disease diagnostics.

Authors

Institutions

Publication Details

Journal
Photoacoustics
Published
2025-06-16
DOI
https://doi.org/10.1016/j.pacs.2025.100744
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High spectral energy density all-fiber nanosecond pulsed 1.7 μm light source for photoacoustic microscopy

Soon‐Woo Cho, Tae Won Nam, Brett E. Bouma, Chang‐Seok Kim et al.
1 citations
Photoacoustics
Photoacoustic and Ultrasonic Imaging
0.67
article

High spectral energy density all-fiber nanosecond pulsed 1.7 μm light source for photoacoustic microscopy

Soon‐Woo Cho, Tae Won Nam, Brett E. Bouma, Chang‐Seok Kim, Yuon Song, Seongjin Bak, Hwidon Lee, Dong‐Wook Han, Jeesu Kim, Sang Min Park
article en
1 citations

Abstract

We present a high spectral energy density all-fiber nanosecond pulsed 1.7 μm light source specifically designed for photoacoustic microscopy (PAM). The system targets the 1st overtone absorption of C-H bonds near 1720 nm within the near-infrared-III (NIR-III) window, where lipids exhibit strong optical absorption, and tissues benefit from reduced scattering and high permissible fluence. To achieve narrow-linewidth, high pulse energy, and high pulse repetition rate (PRR), we developed a master oscillator fiber amplifier architecture based on stimulated Raman scattering. A 1589.80 nm Raman pump and a custom-built narrow-linewidth Raman seed laser were employed to generate spectrally pure 1719.44 nm pulses (∼0.10 nm linewidth). The proposed light source delivers nanosecond pulses (∼5 ns) with high pulse energy (≥2.2 μJ) and tunable PRRs up to 300 kHz, resulting in a spectral energy density of approximately 22 μJ/nm-significantly higher than that of conventional 1.7 μm light sources. Performance of the NIR-PAM system was validated through resolution testing with a 1951 USAF target, demonstrating a spatial resolution of approximately 4.14 μm and an axial resolution of approximately 85.5 μm. Phantom imaging of CH<sub>2</sub>-rich polymer films and ex vivo lipid-rich biological tissues confirmed the system's high spatial fidelity and strong contrast for lipid-specific structures. This compact, stable, and spectrally refined light source with high spectral energy density can offer an effective solution for high-resolution, label-free molecular imaging and represents a promising platform for clinical photoacoustic imaging applications involving lipid detection and metabolic disease diagnostics.

PhotoacousticsVol. 44
Harvard University (US), Duke University (US), Massachusetts General Hospital (US), Pusan National University (KR)
Ministry of Health and Welfare, Korea Health Industry Development Institute, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Affordable and clean energy
Openalex Percentile: Top 30%
Photoacoustic and Ultrasonic Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.