GORE® CARDIOFORM ASD occluder thrombus in a patient of rheumatoid arthritis occurred three days after deployment

A 67-year-old female patient with rheumatoid arthritis that was well suppressed by medications except for steroids had catheter closure of the secundum atrial septal defect (ASD). After the administration of aspirin and intravenous heparin, a 32-mm of GORE® CARDIOFORM ASD occluder was successfully deployed. On postprocedural day 3, transthoracic echocardiography showed mobile echogenic mass of 9 mm on the right side of the device. Intravenous heparin 10 IU/kg/hr was administrated continuously, and clopidogrel was added. On the following day, the mobile mass was not visible. Even though the occurrence rate of device thrombus is not high, device thrombosis can become a major complication of device closure of ASD because it may cause systemic and/or pulmonary embolism. Administration of dual antiplatelet therapy or other anticoagulant therapy should be considered if the patients have a higher risk of thrombosis.

Authors

Publication Details

Journal
International Journal of Cardiology Congenital Heart Disease
Published
2025-06-16
DOI
https://doi.org/10.1016/j.ijcchd.2025.100600
Primary Topic
Cardiovascular Effects of Exercise
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

GORE® CARDIOFORM ASD occluder thrombus in a patient of rheumatoid arthritis occurred three days after deployment

Yusuke Shigemitsu, Naomi Nakagawa, Kengo Okamoto
International Journal of Cardiology Congenital Heart Disease
Cardiovascular Effects of Exercise
article

GORE® CARDIOFORM ASD occluder thrombus in a patient of rheumatoid arthritis occurred three days after deployment

Yusuke Shigemitsu, Naomi Nakagawa, Kengo Okamoto
article en

Abstract

A 67-year-old female patient with rheumatoid arthritis that was well suppressed by medications except for steroids had catheter closure of the secundum atrial septal defect (ASD). After the administration of aspirin and intravenous heparin, a 32-mm of GORE® CARDIOFORM ASD occluder was successfully deployed. On postprocedural day 3, transthoracic echocardiography showed mobile echogenic mass of 9 mm on the right side of the device. Intravenous heparin 10 IU/kg/hr was administrated continuously, and clopidogrel was added. On the following day, the mobile mass was not visible. Even though the occurrence rate of device thrombus is not high, device thrombosis can become a major complication of device closure of ASD because it may cause systemic and/or pulmonary embolism. Administration of dual antiplatelet therapy or other anticoagulant therapy should be considered if the patients have a higher risk of thrombosis.

International Journal of Cardiology Congenital Heart DiseaseVol. 21
Openalex Percentile: Top 76%
Cardiovascular Effects of Exercise
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

GORE® CARDIOFORM ASD occluder thrombus in a patient of rheumatoid arthritis occurred three days after deployment — Yusuke Shigemitsu, Naomi Nakagawa, et al. · International Journal of Cardiology Congenital Heart Disease (2025) | TGRS Research Map | TGRS