Round-trip efficiencies of green ammonia and green hydrogen
The water electrolysis voltage of conventional green ammonia was 1.84 V. The voltage with the same energy consumption of gray ammonia was 1.50 V, which was similar to the thermoneutral voltage (1.48 V). The round-trip efficiencies using overseas transportation 10,000 km of green ammonia increased with decreasing water electrolysis voltage, having high volumetric energy density 3530 Wh/L in the liquid state. The round-trip efficiencies were 23–42% depending on the voltage reduction from 1.84 to 1.48 V and power generation systems. In addition, the round-trip efficiencies using land transportation (pipeline) of green hydrogen also increased with decreasing water electrolysis voltage. The round-trip efficiencies were 28–52%, although the volumetric energy density was below 0.01 of liquid ammonia. • Water electrolysis voltage with the same energy usage of gray ammonia was 1.50 V. • The water electrolysis voltage was changed from 1.84 to thermoneutral voltage 1.48 V. • Round-trip efficiencies increased with decreasing water electrolysis voltage. • Round-trip efficiencies also depended on power generation systems. • The efficiencies of green NH 3 and green H 2 were 23–42% and 28–52%, respectively.
Authors
- Yoshitsugu Kojima (ORCID: https://orcid.org/0000-0003-3466-4908)
Institutions
- Hiroshima University (JP)
Publication Details
- Journal
- Next Energy
- Published
- 2025-06-16
- DOI
- https://doi.org/10.1016/j.nxener.2025.100340
- Citations
- 1
- Primary Topic
- Ammonia Synthesis and Nitrogen Reduction
- Type
- article
- Field-Weighted Citation Impact
- 0.39