Spectrophotometric Determination of Lead in Wastewater from the Battery Industry Based on the Interaction with EDTA Disodium Salt

In addressing the imperative need to assess lead (Pb) concentrations in water due to its heightened toxicity even at minimal levels, this study seeks to overcome challenges in current testing methodologies. Existing approaches often rely on expensive equipment, limiting their accessibility and widespread application. To address this issue, this investigation introduces a simple, rapid, and selective spectrophotometric method for the precise quantification of Pb2+ in aqueous solutions. This method is based on the reaction of Pb2+ with ethylenediaminetetraacetic acid (EDTA) in an ammonia buffer solution, with an absorption maximum observed at 240 nm. The study was conducted under varying parameters, including EDTA concentration, pH of the medium, the presence of organic compounds, and interference effects. The calibration curve demonstrated linearity within the range of 0.5–20 mg/L, with a correlation coefficient (R2) of 0.999, using an ultraviolet-visible spectrophotometer at a λmax of 240 nm. The apparent molar absorption coefficient and limit of detection of Pb2+ were found to be 2.19 × 104 L/ (mol cm) and 0.44 mg/L, respectively. The relative standard deviation for five replicates was less than 2%. Crucially, interference from other ions (Na+, K+, Ca2+, Mg2+, Cu2+, Zn2+, Fe2+, Co2+, Cd2+, and Al3+) was negligible. The proposed method was successfully applied to determine Pb2+ concentrations in battery wastewater samples. The results obtained with the present method were comparable to those from atomic absorption spectroscopy and exhibited high accuracy and excellent precision. These compelling results underscore the method’s efficacy, establishing it as a practical and cost-effective approach for diverse Pb2+ determination applications.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2025-05-01
DOI
https://doi.org/10.1134/s1061934824603943
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spectrophotometric Determination of Lead in Wastewater from the Battery Industry Based on the Interaction with EDTA Disodium Salt

Afaf Lalmi, Ammar Ouahab, Chahrazad Amrane, Sabrina Tamersit et al.
Journal of Analytical Chemistry
Electrochemical Analysis and Applications
article

Spectrophotometric Determination of Lead in Wastewater from the Battery Industry Based on the Interaction with EDTA Disodium Salt

Afaf Lalmi, Ammar Ouahab, Chahrazad Amrane, Sabrina Tamersit, Salima Hamadouche
article en

Abstract

In addressing the imperative need to assess lead (Pb) concentrations in water due to its heightened toxicity even at minimal levels, this study seeks to overcome challenges in current testing methodologies. Existing approaches often rely on expensive equipment, limiting their accessibility and widespread application. To address this issue, this investigation introduces a simple, rapid, and selective spectrophotometric method for the precise quantification of Pb2+ in aqueous solutions. This method is based on the reaction of Pb2+ with ethylenediaminetetraacetic acid (EDTA) in an ammonia buffer solution, with an absorption maximum observed at 240 nm. The study was conducted under varying parameters, including EDTA concentration, pH of the medium, the presence of organic compounds, and interference effects. The calibration curve demonstrated linearity within the range of 0.5–20 mg/L, with a correlation coefficient (R2) of 0.999, using an ultraviolet-visible spectrophotometer at a λmax of 240 nm. The apparent molar absorption coefficient and limit of detection of Pb2+ were found to be 2.19 × 104 L/ (mol cm) and 0.44 mg/L, respectively. The relative standard deviation for five replicates was less than 2%. Crucially, interference from other ions (Na+, K+, Ca2+, Mg2+, Cu2+, Zn2+, Fe2+, Co2+, Cd2+, and Al3+) was negligible. The proposed method was successfully applied to determine Pb2+ concentrations in battery wastewater samples. The results obtained with the present method were comparable to those from atomic absorption spectroscopy and exhibited high accuracy and excellent precision. These compelling results underscore the method’s efficacy, establishing it as a practical and cost-effective approach for diverse Pb2+ determination applications.

Journal of Analytical ChemistryVol. 80(5)
University of Batna 1 (DZ)
Clean water and sanitation
Openalex Percentile: Top 87%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.