Simultaneous Determination of Nickel(II), Copper(II), and Cobalt(II) in Environmental Samples at Trace Levels by Reversed-Phase High-Performance Liquid Chromatography Using Shiff Base Complexes

A new method for the simultaneous determination of Ni(II), Cu(II), and Co(II) ions in environmental samples by reversed-phase liquid chromatography was developed. The developed method is based on the synthesis of the quadrivalent Schiff base 6,6'-((1E,1'E)-(ethane-1,2-diylbis(azaneylylidene))bis(methaneylylidene))bis(3-methoxyphenol) by the condensation reaction between 2-hydroxy-4-methoxybenzaldehyde and ethylenediamine. The resulting Schiff base was used as a chelating agent to convert the targeted ions into metal-ligand complexes within 1 min, which were extracted on an octadecylsilane (ODS) solid-phase extraction mini-column and then injected into a reversed-phase high-performance liquid chromatography system. Sufficient separation of the metal-ligand complexes was achieved on a GL Sciences Intersil ODS-3 column with a mobile phase composition of methanol-acetonitrile-water (30 : 30 : 40, v/v) within 6 min and detection by an ultraviolet detector at 254 nm. The limits of detection were found to be 0.45, 0.40, and 1.47 µg/L for Co2+, Cu2+, and Ni2+, respectively. Recoveries from water samples ranged from 97.4 to 103.6%, with relative standard deviation values between 0.4 and 1.7%. While the targeted metal ions were not detected in a sample from the remote upstream area of the Kabaca Stream (Artvin, Turkey), concentrations were found to be 116.4 µg/L for Cu2+ and 32.9 µg/L for Ni2+ in a sample taken from the Kabaca Stream near the industrial area (Artvin, Turkey). Co2+ was below the limit of detection in both cases. In addition, the developed method was also validated using the inductively coupled plasma optical emission spectrometry technique.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2025-05-01
DOI
https://doi.org/10.1134/s1061934825700303
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous Determination of Nickel(II), Copper(II), and Cobalt(II) in Environmental Samples at Trace Levels by Reversed-Phase High-Performance Liquid Chromatography Using Shiff Base Complexes

Mustafa Umut Konanç, Adem Asan
1 citations
Journal of Analytical Chemistry
Analytical chemistry methods development
0.75
article

Simultaneous Determination of Nickel(II), Copper(II), and Cobalt(II) in Environmental Samples at Trace Levels by Reversed-Phase High-Performance Liquid Chromatography Using Shiff Base Complexes

Mustafa Umut Konanç, Adem Asan
article en
1 citations

Abstract

A new method for the simultaneous determination of Ni(II), Cu(II), and Co(II) ions in environmental samples by reversed-phase liquid chromatography was developed. The developed method is based on the synthesis of the quadrivalent Schiff base 6,6'-((1E,1'E)-(ethane-1,2-diylbis(azaneylylidene))bis(methaneylylidene))bis(3-methoxyphenol) by the condensation reaction between 2-hydroxy-4-methoxybenzaldehyde and ethylenediamine. The resulting Schiff base was used as a chelating agent to convert the targeted ions into metal-ligand complexes within 1 min, which were extracted on an octadecylsilane (ODS) solid-phase extraction mini-column and then injected into a reversed-phase high-performance liquid chromatography system. Sufficient separation of the metal-ligand complexes was achieved on a GL Sciences Intersil ODS-3 column with a mobile phase composition of methanol-acetonitrile-water (30 : 30 : 40, v/v) within 6 min and detection by an ultraviolet detector at 254 nm. The limits of detection were found to be 0.45, 0.40, and 1.47 µg/L for Co2+, Cu2+, and Ni2+, respectively. Recoveries from water samples ranged from 97.4 to 103.6%, with relative standard deviation values between 0.4 and 1.7%. While the targeted metal ions were not detected in a sample from the remote upstream area of the Kabaca Stream (Artvin, Turkey), concentrations were found to be 116.4 µg/L for Cu2+ and 32.9 µg/L for Ni2+ in a sample taken from the Kabaca Stream near the industrial area (Artvin, Turkey). Co2+ was below the limit of detection in both cases. In addition, the developed method was also validated using the inductively coupled plasma optical emission spectrometry technique.

Journal of Analytical ChemistryVol. 80(5)
Artvin Coruh University (TR), Ondokuz Mayıs University (TR)
Openalex Percentile: Top 31%
Analytical chemistry methods development
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.