Bedside Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Assessing Increased Intracranial Pressure: An Observational Study

Background Traumatic brain injury (TBI) is a leading cause of disability and mortality, particularly in resource-limited settings where advanced neuromonitoring tools are often unavailable. Elevated intracranial pressure (ICP) is a serious and potentially life-threatening complication of TBI. Traditional methods for monitoring ICP are invasive, expensive, and require specialized expertise. Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) offers a noninvasive, real-time, and radiation-free alternative for assessing ICP. Objective This study aimed to evaluate the diagnostic accuracy of bedside ONSD measurement in detecting elevated ICP among neurotrauma patients, using CT imaging as the reference standard. Additionally, it explored the relationship between ONSD measurements, TBI severity, and neurological outcomes. Methods A prospective observational study was conducted on 100 adult patients with TBI, in whom bilateral ONSD measurements were obtained using a high-frequency linear ultrasound probe. Based on CT scan findings, patients were classified as having either raised or normal ICP. Statistical analyses included sensitivity, specificity, positive and negative predictive values, receiver operating characteristic curve analysis, and logistic regression to assess the diagnostic and prognostic utility of ONSD. Results Raised ICP was observed in 67% of patients, most of whom had moderate to severe TBI. ONSD values increased with injury severity: mild (4.53 ± 0.14 mm), moderate (5.24 ± 0.15 mm), and severe (5.90 ± 0.25 mm). A cutoff value of 5.2 mm demonstrated 95.5% sensitivity, 93.9% specificity, and an area under the curve of 0.96. An ONSD greater than 5.5 mm was strongly associated with poor neurological outcomes (Glasgow Outcome Scale scores 1-3), with an OR of 4.6 (p < 0.001). Conclusions Bedside ultrasonographic measurement of ONSD is a reliable and accurate method for detecting elevated ICP in TBI patients. It correlates strongly with both injury severity and clinical outcomes, making it a valuable tool in emergency and intensive care settings. Further studies comparing this technique with invasive monitoring methods and evaluating long-term outcomes are warranted.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-06-16
DOI
https://doi.org/10.7759/cureus.86163
Primary Topic
Traumatic Brain Injury and Neurovascular Disturbances
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bedside Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Assessing Increased Intracranial Pressure: An Observational Study

Saurav Shekhar, Suman Lata, Preeti Sharma, Raj Singh et al.
1 links
Cureus
Traumatic Brain Injury and Neurovascular Disturbances
article

Bedside Ultrasonographic Measurement of Optic Nerve Sheath Diameter for Assessing Increased Intracranial Pressure: An Observational Study

Saurav Shekhar, Suman Lata, Preeti Sharma, Raj Singh, Amit Kumar, Ranjeet Rana De, Nitin Kumar
article en

Abstract

Background Traumatic brain injury (TBI) is a leading cause of disability and mortality, particularly in resource-limited settings where advanced neuromonitoring tools are often unavailable. Elevated intracranial pressure (ICP) is a serious and potentially life-threatening complication of TBI. Traditional methods for monitoring ICP are invasive, expensive, and require specialized expertise. Ultrasonographic measurement of the optic nerve sheath diameter (ONSD) offers a noninvasive, real-time, and radiation-free alternative for assessing ICP. Objective This study aimed to evaluate the diagnostic accuracy of bedside ONSD measurement in detecting elevated ICP among neurotrauma patients, using CT imaging as the reference standard. Additionally, it explored the relationship between ONSD measurements, TBI severity, and neurological outcomes. Methods A prospective observational study was conducted on 100 adult patients with TBI, in whom bilateral ONSD measurements were obtained using a high-frequency linear ultrasound probe. Based on CT scan findings, patients were classified as having either raised or normal ICP. Statistical analyses included sensitivity, specificity, positive and negative predictive values, receiver operating characteristic curve analysis, and logistic regression to assess the diagnostic and prognostic utility of ONSD. Results Raised ICP was observed in 67% of patients, most of whom had moderate to severe TBI. ONSD values increased with injury severity: mild (4.53 ± 0.14 mm), moderate (5.24 ± 0.15 mm), and severe (5.90 ± 0.25 mm). A cutoff value of 5.2 mm demonstrated 95.5% sensitivity, 93.9% specificity, and an area under the curve of 0.96. An ONSD greater than 5.5 mm was strongly associated with poor neurological outcomes (Glasgow Outcome Scale scores 1-3), with an OR of 4.6 (p < 0.001). Conclusions Bedside ultrasonographic measurement of ONSD is a reliable and accurate method for detecting elevated ICP in TBI patients. It correlates strongly with both injury severity and clinical outcomes, making it a valuable tool in emergency and intensive care settings. Further studies comparing this technique with invasive monitoring methods and evaluating long-term outcomes are warranted.

CureusVol. 17(6)
Indira Gandhi Institute of Medical Sciences (IN)
Openalex Percentile: Top 78%
Traumatic Brain Injury and Neurovascular Disturbances
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.