Calibration and Validation of Phase One Industrial Cameras

Abstract. JOANNEUM RESEARCH has reviewed the geometric lab calibration workflow of Phase One A/S, investigating the calibration method from a theoretical point of view, but also by evaluation of an existing calibration project from their new lab in Denver, USA. In addition, two iXM-RS150F reference cameras (50mm and 150mm lens) have been calibrated in the measurement lab of the Institute of Engineering Geodesy and Measurement Systems (IGMS) at Technical University Graz, Austria and results have been compared with the Phase One calibration certificates. Although correctness and quality of the Phase One calibration workflow could be confirmed, small but significant differences exist and can only be explained using various hypothesis e.g. about the influence of different environmental conditions during calibration. As it is not possible from direct comparison to decide which parameter set is the better or even correct one, methods to validate a camera calibration in the lab have been investigated which exist e.g. for acceptance testing of 3D optical measurement systems. It was found that existing methods based on capturing dedicated test bodies using a dense photo network and comparing reconstructed 3D lengths with the calibrated ones cannot be easily transferred to aerial camera systems, especially for longer focal lengths. Therefore, a new lab validation approach has been developed and tested using more available geodetic level rods, LSM matching of the bar code and an algorithm to transfer the length measurement from the image to object space without need for standard 3D point reconstruction.

Authors

Institutions

Publication Details

Journal
˜The œinternational archives of the photogrammetry, remote sensing and spatial information sciences/International archives of the photogrammetry, remote sensing and spatial information sciences
Published
2025-06-16
DOI
https://doi.org/10.5194/isprs-archives-xlviii-1-w4-2025-73-2025
Primary Topic
Industrial Vision Systems and Defect Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration and Validation of Phase One Industrial Cameras

Helmut Woschitz, Richard Ladstädter, Roland Perko, Karlheinz Gutjahr
˜The œinternational archives of the photogrammetry, remote sensing and spatial information sciences/International archives of the photogrammetry, remote sensing and spatial information sciences
Industrial Vision Systems and Defect Detection
article

Calibration and Validation of Phase One Industrial Cameras

Helmut Woschitz, Richard Ladstädter, Roland Perko, Karlheinz Gutjahr
article en

Abstract

Abstract. JOANNEUM RESEARCH has reviewed the geometric lab calibration workflow of Phase One A/S, investigating the calibration method from a theoretical point of view, but also by evaluation of an existing calibration project from their new lab in Denver, USA. In addition, two iXM-RS150F reference cameras (50mm and 150mm lens) have been calibrated in the measurement lab of the Institute of Engineering Geodesy and Measurement Systems (IGMS) at Technical University Graz, Austria and results have been compared with the Phase One calibration certificates. Although correctness and quality of the Phase One calibration workflow could be confirmed, small but significant differences exist and can only be explained using various hypothesis e.g. about the influence of different environmental conditions during calibration. As it is not possible from direct comparison to decide which parameter set is the better or even correct one, methods to validate a camera calibration in the lab have been investigated which exist e.g. for acceptance testing of 3D optical measurement systems. It was found that existing methods based on capturing dedicated test bodies using a dense photo network and comparing reconstructed 3D lengths with the calibrated ones cannot be easily transferred to aerial camera systems, especially for longer focal lengths. Therefore, a new lab validation approach has been developed and tested using more available geodetic level rods, LSM matching of the bar code and an algorithm to transfer the length measurement from the image to object space without need for standard 3D point reconstruction.

˜The œinternational archives of the photogrammetry, remote sensing and spatial information sciences/International archives of the photogrammetry, remote sensing and spatial information sciencesVol. XLVIII-1/W4-2025
Joanneum Research (AT), Graz University of Technology (AT)
Openalex Percentile: Top 81%
Industrial Vision Systems and Defect Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.