• Novel reverse scatter correction method for CT imaging of nuclear graphite. • Predicts transmitted photons, estimates scattered photons via low-frequency distribution. • Superior scatter artifact reduction vs. Monte Carlo and machine learning. • Enhances image uniformity, improves defect recognition and detection. • Computationally efficient, suitable for high-temperature gas-cooled reactor lines. The structural integrity of high-temperature gas-cooled reactors (HTGRs) is reliant on over 3000 carbon/graphite components, each of which necessitates computed tomography (CT) scanning for non-destructive testing prior to deployment, as stipulated by the reactor’s technical specifications. Despite the critical role of CT scans, they are frequently marred by significant scatter artifacts due to the detection of scattered photons, which compromises image uniformity and diminishes the system’s ability to detect defects. Our research presents a novel inverse scatter photon prediction model that addresses the shortcomings of traditional models by utilizing empirical data and the inherent properties of nuclear graphite/carbon components. This method begins by mapping and subtracting the transmitted photons from the projection data, followed by estimating the scattered photon distribution based on their low-frequency characteristics. The experimental results confirm that our method not only surpasses Monte-Carlo simulations and machine learning in reducing scatter artifacts but also meets the efficiency requirements for online detection. Our quantitative analyses indicate that our approach achieves the highest Defects Recognition Performance (DRP) value, which underscores a notable enhancement in the system’s ability to detect defects. We are confident that our findings will significantly enhance the defect detection capabilities of the CT scanning system, thereby contributing to the overall safety and reliability of HTGR operations.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Design
Published
2025-06-16
DOI
https://doi.org/10.1016/j.nucengdes.2025.114236
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A reverse scatter correction method for CT images of nuclear graphite components

Ximing Liu, Tianchen Zeng, Peng Cong, Yuewen Sun et al.
1 links
Nuclear Engineering and Design
Medical Imaging Techniques and Applications
article

A reverse scatter correction method for CT images of nuclear graphite components

Ximing Liu, Tianchen Zeng, Peng Cong, Yuewen Sun, J. L. Fu, Guangduo Xu
article en

Abstract

• Novel reverse scatter correction method for CT imaging of nuclear graphite. • Predicts transmitted photons, estimates scattered photons via low-frequency distribution. • Superior scatter artifact reduction vs. Monte Carlo and machine learning. • Enhances image uniformity, improves defect recognition and detection. • Computationally efficient, suitable for high-temperature gas-cooled reactor lines. The structural integrity of high-temperature gas-cooled reactors (HTGRs) is reliant on over 3000 carbon/graphite components, each of which necessitates computed tomography (CT) scanning for non-destructive testing prior to deployment, as stipulated by the reactor’s technical specifications. Despite the critical role of CT scans, they are frequently marred by significant scatter artifacts due to the detection of scattered photons, which compromises image uniformity and diminishes the system’s ability to detect defects. Our research presents a novel inverse scatter photon prediction model that addresses the shortcomings of traditional models by utilizing empirical data and the inherent properties of nuclear graphite/carbon components. This method begins by mapping and subtracting the transmitted photons from the projection data, followed by estimating the scattered photon distribution based on their low-frequency characteristics. The experimental results confirm that our method not only surpasses Monte-Carlo simulations and machine learning in reducing scatter artifacts but also meets the efficiency requirements for online detection. Our quantitative analyses indicate that our approach achieves the highest Defects Recognition Performance (DRP) value, which underscores a notable enhancement in the system’s ability to detect defects. We are confident that our findings will significantly enhance the defect detection capabilities of the CT scanning system, thereby contributing to the overall safety and reliability of HTGR operations.

Nuclear Engineering and DesignVol. 442
Key Laboratory of Nuclear Radiation and Nuclear Energy Technology (CN), Tsinghua University (CN)
Openalex Percentile: Top 79%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.