An in vitro study to assess halide-containing glass-coated surgical suture for bone regeneration in implant surgery

Polyglycolic acid (PGA) suture is a synthetic, absorbable, and biocompatible material. However, it lacks bioactivity and cannot bond with osseous tissue. Bioactive glasses have the ability to form surface apatite and bond with bone, but they are brittle and therefore difficult to shape in the operating room. PGA sutures were coated with chloride-silicate glass (CSG) using the slurry dipping technique. The CSG-coated sutures were characterized before and after immersion in simulated body fluid (SBF) by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS). The adhesion of the glass coating to the PGA suture was assessed by the knot performance test. The bioactivity of the coated sutures was investigated in SBF) after 7, 14, 21, and 28 days of immersion. The pH variation of the SBF was measured using a pH meter. Tensile strength of the bare and coated sutures was quantified using a universal testing machine before and after immersion in SBF, and the cytotoxicity was assessed using osteoblast-like cells after 24, 48, 72, and 168h. The results revealed that the coating covered and adhered to the surgical suture. The coated suture had the ability to form a small size or low amount of apatite after 7 days of immersion. The CSG coating exhibited a tendency to increase the tensile strength of the suture, but this increase was not statistically significant. The glass coating was not cytotoxic to osteoblast-like cells. It is suggested that PGA sutures coated with CSG could be used as a potential material to promote bone regeneration.

Authors

Institutions

Publication Details

Journal
Journal of Biomaterials Science Polymer Edition
Published
2025-06-16
DOI
https://doi.org/10.1080/09205063.2025.2504022
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An in vitro study to assess halide-containing glass-coated surgical suture for bone regeneration in implant surgery

Simon C.F. Rawlinson, Ahmed Al‐Noaman
1 links
Journal of Biomaterials Science Polymer Edition
Bone Tissue Engineering Materials
article

An in vitro study to assess halide-containing glass-coated surgical suture for bone regeneration in implant surgery

Simon C.F. Rawlinson, Ahmed Al‐Noaman
article en

Abstract

Polyglycolic acid (PGA) suture is a synthetic, absorbable, and biocompatible material. However, it lacks bioactivity and cannot bond with osseous tissue. Bioactive glasses have the ability to form surface apatite and bond with bone, but they are brittle and therefore difficult to shape in the operating room. PGA sutures were coated with chloride-silicate glass (CSG) using the slurry dipping technique. The CSG-coated sutures were characterized before and after immersion in simulated body fluid (SBF) by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and scanning electron microscopy-energy dispersive spectroscopy (SEM-EDS). The adhesion of the glass coating to the PGA suture was assessed by the knot performance test. The bioactivity of the coated sutures was investigated in SBF) after 7, 14, 21, and 28 days of immersion. The pH variation of the SBF was measured using a pH meter. Tensile strength of the bare and coated sutures was quantified using a universal testing machine before and after immersion in SBF, and the cytotoxicity was assessed using osteoblast-like cells after 24, 48, 72, and 168h. The results revealed that the coating covered and adhered to the surgical suture. The coated suture had the ability to form a small size or low amount of apatite after 7 days of immersion. The CSG coating exhibited a tendency to increase the tensile strength of the suture, but this increase was not statistically significant. The glass coating was not cytotoxic to osteoblast-like cells. It is suggested that PGA sutures coated with CSG could be used as a potential material to promote bone regeneration.

Journal of Biomaterials Science Polymer EditionVol. 36(16)
Queen Mary University of London (GB), University of Babylon (IQ)
Zero hunger
Openalex Percentile: Top 87%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An in vitro study to assess halide-containing glass-coated surgical suture for bone regeneration in implant surgery — Simon C.F. Rawlinson, Ahmed Al‐Noaman · Journal of Biomaterials Science Polymer Edition (2025) | TGRS Research Map | TGRS