Kinetically tunable, subzero-active, visual time–temperature indicators based on the permanganate–oxalate reaction

Biological products and specimens often require consistent ultracold storage to preserve their integrity. Existing time-temperature indicators (TTIs) are inadequate for monitoring ultracold conditions at the individual aliquot level. We adapted the autocatalytic permanganate-oxalate reaction to create visual TTIs functional below 0 °C. Using eutectic compositions of LiClO<sub>4</sub>, NaClO<sub>4</sub>, and Mg(ClO<sub>4</sub>)<sub>2</sub>, we depressed the melting points of the reaction mixtures to -18 °C, -37 °C, and -67 °C, respectively. The incorporation of perchlorate salts as antifreeze systems did not derail the kinetic behavior of the permanganate-oxalate reaction and allowed the reactions to pause below their melting points. Here, we developed and characterized eight customized TTIs, running from five minutes at 25 °C to 7 days at -20 °C. Temperature sensitivity was consistent with Arrhenius behavior (i.e., exponential increases in run time with linear decreases in temperature). The TTIs exhibited good accuracy and reproducibility, with within-batch and between-batch run-time precision at the targeted temperatures of ≤ 4.8% CV and ≤ 7.5% CV, respectively. The average absorbance vs. time trajectories, expressed as RMSD %CVs, were 4.5% for intra-batch and 10.4% for inter-batch runs. Indicators withstood multiple freeze/thaw cycles or extended pre-freezing periods with minimal impact on reaction kinetics. Once activated and stored below their melting points, TTIs maintained color intensity for at least 12 months. This work establishes the permanganate-oxalate system in eutectic perchlorate-based antifreeze solutions as a simple, inexpensive approach for ultracold-active TTIs, offering customizable kinetics and robust performance. The described TTIs can serve to improve quality monitoring of biologicals and biospecimens during ultracold storage and handling.

Authors

Institutions

Publication Details

Journal
Reaction Chemistry & Engineering
Published
2025-01-01
DOI
https://doi.org/10.1039/d5re00192g
Primary Topic
bioluminescence and chemiluminescence research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Kinetically tunable, subzero-active, visual time–temperature indicators based on the permanganate–oxalate reaction

Jorvani Cruz Villarreal, Anika Li, Michael S. Owens, Chad R. Borges et al.
Reaction Chemistry & Engineering
bioluminescence and chemiluminescence research
article

Kinetically tunable, subzero-active, visual time–temperature indicators based on the permanganate–oxalate reaction

Jorvani Cruz Villarreal, Anika Li, Michael S. Owens, Chad R. Borges, Nilojan Jehanathan, Emil Ljungberg
article en

Abstract

Biological products and specimens often require consistent ultracold storage to preserve their integrity. Existing time-temperature indicators (TTIs) are inadequate for monitoring ultracold conditions at the individual aliquot level. We adapted the autocatalytic permanganate-oxalate reaction to create visual TTIs functional below 0 °C. Using eutectic compositions of LiClO<sub>4</sub>, NaClO<sub>4</sub>, and Mg(ClO<sub>4</sub>)<sub>2</sub>, we depressed the melting points of the reaction mixtures to -18 °C, -37 °C, and -67 °C, respectively. The incorporation of perchlorate salts as antifreeze systems did not derail the kinetic behavior of the permanganate-oxalate reaction and allowed the reactions to pause below their melting points. Here, we developed and characterized eight customized TTIs, running from five minutes at 25 °C to 7 days at -20 °C. Temperature sensitivity was consistent with Arrhenius behavior (i.e., exponential increases in run time with linear decreases in temperature). The TTIs exhibited good accuracy and reproducibility, with within-batch and between-batch run-time precision at the targeted temperatures of ≤ 4.8% CV and ≤ 7.5% CV, respectively. The average absorbance vs. time trajectories, expressed as RMSD %CVs, were 4.5% for intra-batch and 10.4% for inter-batch runs. Indicators withstood multiple freeze/thaw cycles or extended pre-freezing periods with minimal impact on reaction kinetics. Once activated and stored below their melting points, TTIs maintained color intensity for at least 12 months. This work establishes the permanganate-oxalate system in eutectic perchlorate-based antifreeze solutions as a simple, inexpensive approach for ultracold-active TTIs, offering customizable kinetics and robust performance. The described TTIs can serve to improve quality monitoring of biologicals and biospecimens during ultracold storage and handling.

Reaction Chemistry & EngineeringVol. 10(8)
Arizona State University (US), CryoLife (United States) (US)
National Cancer Institute
Openalex Percentile: Top 87%
bioluminescence and chemiluminescence research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.