Assessing the performance of novel and sustainable electrochemical sensor based on cobalt sulfide/upcycled reduced graphene oxide from plastic waste

Developing electrochemical sensors that are both highly sensitive and environmentally sustainable is a pressing need in modern healthcare and environmental analysis. In this study, a cobalt sulfide/reduced graphene oxide (CoS/rGO) nanocomposite was synthesized via a straightforward, low-cost method that integrates thiourea and cobalt acetate to form CoS, with rGO derived from recycled plastic waste. The structural and electrochemical properties of the composites were systematically investigated using cyclic voltammetry (CV) and linear sweep voltammetry (LSV). The addition of rGO, varied from 0 to 50 wt%, notably enhanced the electrical conductivity and surface activity of the sensing interface. Among the tested formulations, the composite containing 40 wt% rGO exhibited the highest performance, achieving a sensitivity of 12.4 μA mM −1 cm −2 and a detection limit of 0.2 μM, which is approximately 7.5 times lower than that of pristine CoS. Kinetic analysis confirmed that the sensing mechanism follows a pseudo-second-order model, indicative of a chemisorption-driven interaction between paracetamol molecules and the sensor surface. The sensor displayed excellent operational stability over 100 consecutive cycles and high repeatability with a relative standard deviation below 2.5 %. This work demonstrates a novel, green strategy for sensor fabrication that effectively combines electronic functionality with environmental sustainability, making the CoS/rGO nanocomposite a viable platform for next-generation sensing technologies. • CoS/rGO synthesized through well-mixed powder of CoS with rGO obtained from plastic waste. • The paracetamol sensing mechanism involving adsorption and electrochemical reactions. • CoS/rGO with 40 wt% rGO loading shows LOD at (S/N = 3) of 0. 2 μM L −1 . • LOD was improved by 7.5 times for the CoS/rGO electrode compared with pristine CoS electrode.

Authors

Institutions

Publication Details

Journal
Electrochemistry Communications
Published
2025-06-16
DOI
https://doi.org/10.1016/j.elecom.2025.107982
Citations
5
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
3.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the performance of novel and sustainable electrochemical sensor based on cobalt sulfide/upcycled reduced graphene oxide from plastic waste

Arafat Toghan, M. Elsayed Youssef, Sami A. Al‐Hussain, A.A.M. Farag et al.
5 citations
Electrochemistry Communications
Conducting polymers and applications
3.03
article

Assessing the performance of novel and sustainable electrochemical sensor based on cobalt sulfide/upcycled reduced graphene oxide from plastic waste

Arafat Toghan, M. Elsayed Youssef, Sami A. Al‐Hussain, A.A.M. Farag, Mohamed Elnouby, Noha A. Elessawy, N. Roushdy, Sara H. Yousef
article en
5 citations

Abstract

Developing electrochemical sensors that are both highly sensitive and environmentally sustainable is a pressing need in modern healthcare and environmental analysis. In this study, a cobalt sulfide/reduced graphene oxide (CoS/rGO) nanocomposite was synthesized via a straightforward, low-cost method that integrates thiourea and cobalt acetate to form CoS, with rGO derived from recycled plastic waste. The structural and electrochemical properties of the composites were systematically investigated using cyclic voltammetry (CV) and linear sweep voltammetry (LSV). The addition of rGO, varied from 0 to 50 wt%, notably enhanced the electrical conductivity and surface activity of the sensing interface. Among the tested formulations, the composite containing 40 wt% rGO exhibited the highest performance, achieving a sensitivity of 12.4 μA mM −1 cm −2 and a detection limit of 0.2 μM, which is approximately 7.5 times lower than that of pristine CoS. Kinetic analysis confirmed that the sensing mechanism follows a pseudo-second-order model, indicative of a chemisorption-driven interaction between paracetamol molecules and the sensor surface. The sensor displayed excellent operational stability over 100 consecutive cycles and high repeatability with a relative standard deviation below 2.5 %. This work demonstrates a novel, green strategy for sensor fabrication that effectively combines electronic functionality with environmental sustainability, making the CoS/rGO nanocomposite a viable platform for next-generation sensing technologies. • CoS/rGO synthesized through well-mixed powder of CoS with rGO obtained from plastic waste. • The paracetamol sensing mechanism involving adsorption and electrochemical reactions. • CoS/rGO with 40 wt% rGO loading shows LOD at (S/N = 3) of 0. 2 μM L −1 . • LOD was improved by 7.5 times for the CoS/rGO electrode compared with pristine CoS electrode.

Electrochemistry CommunicationsVol. 177
Ain Shams University (EG), Imam Mohammad ibn Saud Islamic University (SA), Alexandria Higher Institute of Engineering and Technology (EG), Egypt-Japan University of Science and Technology (EG), City of Scientific Research and Technological Applications (EG), Higher Institute of Engineering (EG)
Responsible consumption and production
Openalex Percentile: Top 9%
Conducting polymers and applications
3.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.