An AIEgen-based fluorescence probe for ratiometric detection of phosgene in solution and gas

Phosgene, a toxic and asphyxiating gas, poses a significant threat to human health. In this study, a ratiometric fluorescence probe for phosgene detection was synthesized based on the combination of an aggregation-induced emission tetraphenylethylene (TPE) luminophore and rhodamine hydrazide. The probe exhibits a unique and sensitive response to phosgene based on its spirolactam ring-opening properties and nucleophilic reaction with phosgene. Notably, the probe exhibits a significantly enhanced Stokes shift of 103 nm for ratiometric phosgene detection. Additionally, test strips were developed for the detection of gas phosgene under 365 nm hand-held UV lamps. The design and synthesis of these molecules contribute significantly to environmental health and public safety.

Authors

Institutions

Publication Details

Journal
Chemical Communications
Published
2025-01-01
DOI
https://doi.org/10.1039/d5cc01871d
Citations
3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An AIEgen-based fluorescence probe for ratiometric detection of phosgene in solution and gas

Dexin Fu, Ping Yang, Kuiliang Li, Duo‐Duo Hu et al.
3 citations
Chemical Communications
Advanced biosensing and bioanalysis techniques
2.42
article

An AIEgen-based fluorescence probe for ratiometric detection of phosgene in solution and gas

Dexin Fu, Ping Yang, Kuiliang Li, Duo‐Duo Hu, Tian Zhang, Chao He, Wenqiang Xie
article en
3 citations

Abstract

Phosgene, a toxic and asphyxiating gas, poses a significant threat to human health. In this study, a ratiometric fluorescence probe for phosgene detection was synthesized based on the combination of an aggregation-induced emission tetraphenylethylene (TPE) luminophore and rhodamine hydrazide. The probe exhibits a unique and sensitive response to phosgene based on its spirolactam ring-opening properties and nucleophilic reaction with phosgene. Notably, the probe exhibits a significantly enhanced Stokes shift of 103 nm for ratiometric phosgene detection. Additionally, test strips were developed for the detection of gas phosgene under 365 nm hand-held UV lamps. The design and synthesis of these molecules contribute significantly to environmental health and public safety.

Chemical CommunicationsVol. 61(59)
University of Science and Technology of China (CN), Anhui University of Science and Technology (CN)
Anhui University of Science and Technology, Natural Science Foundation of Anhui Province
Openalex Percentile: Top 11%
Advanced biosensing and bioanalysis techniques
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.