Finite element simulation and parametric study of exposed column base plate connections under axial compression and Bi-directional lateral loading

This study numerically investigates the structural performance of exposed steel column base plate (CBP) connections subjected to combined axial compression and bi-directional lateral loading. Unlike traditional approaches that primarily consider uniaxial forces, this research addresses the combined impact of multi-directional forces, which more accurately represent seismic loading conditions. The research employs a comprehensive methodology that integrates experimentally validated finite element analysis (FEA) using ABAQUS. Laboratory tests were conducted on four CBP specimens with varying base plate thicknesses, bolt layouts, and grout thicknesses to capture critical failure modes and hysteretic behavior, in a companion study. The FEA models, validated against those experimental results, successfully simulate the non-linear moment-rotation response, pinching effects, and stiffness degradation under cyclic loading. Parametric studies are performed to explore the influence of key design variables, including axial load magnitude, base plate thickness, anchor bolt layout, bolt diameter, and grout properties. The results reveal that higher axial loads enhance moment capacity but reduce ductility, while bolt layout and diameter significantly influence energy dissipation capacity and failure mechanisms. This research highlights the differences in connection stiffness under unidirectional and bidirectional lateral loading and their impact on the behavior and response of CBP connections. The findings provide a foundation for improving design codes and optimizing the seismic performance of steel-framed structures. • Investigates the behavior of exposed CBP connections under combined axial compression and bi-directional lateral loading. • Comprehensive parametric study considering key factor affecting CBP design. • Investigates moment-rotation behavior, stiffness degradation, and energy dissipation of CBP connections. • Anchor bolt layouts affect flexural capacity, ductility and stiffness. • Design codes tend to overestimate rotational stiffness compared to under bi-directional loading.

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2025-06-16
DOI
https://doi.org/10.1016/j.jobe.2025.113188
Citations
2
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
2.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element simulation and parametric study of exposed column base plate connections under axial compression and Bi-directional lateral loading

A. H. M. Muntasir Billah, Shen Jiang
2 citations
Journal of Building Engineering
Structural Behavior of Reinforced Concrete
2.01
article

Finite element simulation and parametric study of exposed column base plate connections under axial compression and Bi-directional lateral loading

A. H. M. Muntasir Billah, Shen Jiang
article en
2 citations

Abstract

This study numerically investigates the structural performance of exposed steel column base plate (CBP) connections subjected to combined axial compression and bi-directional lateral loading. Unlike traditional approaches that primarily consider uniaxial forces, this research addresses the combined impact of multi-directional forces, which more accurately represent seismic loading conditions. The research employs a comprehensive methodology that integrates experimentally validated finite element analysis (FEA) using ABAQUS. Laboratory tests were conducted on four CBP specimens with varying base plate thicknesses, bolt layouts, and grout thicknesses to capture critical failure modes and hysteretic behavior, in a companion study. The FEA models, validated against those experimental results, successfully simulate the non-linear moment-rotation response, pinching effects, and stiffness degradation under cyclic loading. Parametric studies are performed to explore the influence of key design variables, including axial load magnitude, base plate thickness, anchor bolt layout, bolt diameter, and grout properties. The results reveal that higher axial loads enhance moment capacity but reduce ductility, while bolt layout and diameter significantly influence energy dissipation capacity and failure mechanisms. This research highlights the differences in connection stiffness under unidirectional and bidirectional lateral loading and their impact on the behavior and response of CBP connections. The findings provide a foundation for improving design codes and optimizing the seismic performance of steel-framed structures. • Investigates the behavior of exposed CBP connections under combined axial compression and bi-directional lateral loading. • Comprehensive parametric study considering key factor affecting CBP design. • Investigates moment-rotation behavior, stiffness degradation, and energy dissipation of CBP connections. • Anchor bolt layouts affect flexural capacity, ductility and stiffness. • Design codes tend to overestimate rotational stiffness compared to under bi-directional loading.

Journal of Building EngineeringVol. 111
University of Calgary (CA)
Canadian Institute of Steel Construction
Sustainable cities and communities
Openalex Percentile: Top 14%
Structural Behavior of Reinforced Concrete
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.