Study on the Characteristics of Electrical Tree Partial Discharge According to the Variation of Artificial Void Gap Length in Epoxy Resin

Epoxy resin used in high-voltage power equipment such as molded power transformers and OF power cable joint-boxs is widely used because it has advantages in electrical insulation and stability of mechanical properties. However, when manufacturing power devices, nano and micro void defects occur, and cracks and interfacial defects occur due to thermal expansion coefficient at the interface between the conductor and epoxy microcomposite for a long period of time. In this way, the partial discharge is converted into an electrical tree and the tree is initiated. And it progresses further, ultimately resulting in insulation breakdown. Three types of insulation defects were simulated in epoxy resin: No Void, Void Gap_0.5mm samples. The applied voltage was 13kV/60Hz, and the discharge signal was measured from the voltage application through a microscope and the AE Signal measurement system when Tree-Partial Discharge occurred. To diagnose the deterioration state of Tree-Partial Discharge, the axial tree progression length was measured and evaluated throughout the entire process from the Tree Incubation Period to tree initiation, progression, and destruction. In order to evaluate the characteristics of Tree-Partial Discharge, the waveform of the AE Waveform and the result of FFT (Fast Fourier Transform) execution were converted from time-voltage (amplitude) to frequency-voltage (amplitude) function. In addition, the frequency characteristics of the waveform against the tree-deterioration time were evaluated, and the mechanisms of No Void and void discharge characteristics were analyzed.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2025-05-31
DOI
https://doi.org/10.5370/kiee.2025.74.5.885
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Characteristics of Electrical Tree Partial Discharge According to the Variation of Artificial Void Gap Length in Epoxy Resin

Jae-Jun Park
The Transactions of The Korean Institute of Electrical Engineers
Engineering Applied Research
article

Study on the Characteristics of Electrical Tree Partial Discharge According to the Variation of Artificial Void Gap Length in Epoxy Resin

Jae-Jun Park
article en

Abstract

Epoxy resin used in high-voltage power equipment such as molded power transformers and OF power cable joint-boxs is widely used because it has advantages in electrical insulation and stability of mechanical properties. However, when manufacturing power devices, nano and micro void defects occur, and cracks and interfacial defects occur due to thermal expansion coefficient at the interface between the conductor and epoxy microcomposite for a long period of time. In this way, the partial discharge is converted into an electrical tree and the tree is initiated. And it progresses further, ultimately resulting in insulation breakdown. Three types of insulation defects were simulated in epoxy resin: No Void, Void Gap_0.5mm samples. The applied voltage was 13kV/60Hz, and the discharge signal was measured from the voltage application through a microscope and the AE Signal measurement system when Tree-Partial Discharge occurred. To diagnose the deterioration state of Tree-Partial Discharge, the axial tree progression length was measured and evaluated throughout the entire process from the Tree Incubation Period to tree initiation, progression, and destruction. In order to evaluate the characteristics of Tree-Partial Discharge, the waveform of the AE Waveform and the result of FFT (Fast Fourier Transform) execution were converted from time-voltage (amplitude) to frequency-voltage (amplitude) function. In addition, the frequency characteristics of the waveform against the tree-deterioration time were evaluated, and the mechanisms of No Void and void discharge characteristics were analyzed.

The Transactions of The Korean Institute of Electrical EngineersVol. 74(5)
Clean water and sanitation
Openalex Percentile: Top 86%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.