Analysis of Electro-Magnetic Interference on Underground Cable According to Grounding Methods in AC/DC Hybrid Distribution Networks

Due to the proportion of renewable energy increase, DC systems are in demand and the study on AC/DC Hybrid system is ongoing. The current AC distribution system is characterized by a passive, unidirectional flow of power, which limits power control and causes power loss in AC/DC conversion for DC demands. The AC/DC Hybrid distribution system improves system operational efficiency by integrating DC systems into existing AC system, expanding the capacity for renewable energy integration, and reducing conversion losses from AC to DC. However, depending on the line configuration, AC/DC cables may be positioned adjacently, potentially causing electro-magnetic interference (EMI) between them. This paper proposes the best grounding methods of underground cable which is appropriate to the AC/DC Hybrid distribution system. The validation of the grounding methods of underground cable was performed by Electro-Magnetic Transients Program (EMTP) ATP-Draw.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2025-05-31
DOI
https://doi.org/10.5370/kiee.2025.74.5.784
Primary Topic
Railway Systems and Energy Efficiency
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Electro-Magnetic Interference on Underground Cable According to Grounding Methods in AC/DC Hybrid Distribution Networks

Chul‐Hwan Kim, Sung-Man Kang, Oh‐Seung Kwon, Wook-Won Kim et al.
The Transactions of The Korean Institute of Electrical Engineers
Railway Systems and Energy Efficiency
article

Analysis of Electro-Magnetic Interference on Underground Cable According to Grounding Methods in AC/DC Hybrid Distribution Networks

Chul‐Hwan Kim, Sung-Man Kang, Oh‐Seung Kwon, Wook-Won Kim, Jin‐Sol Song
article en

Abstract

Due to the proportion of renewable energy increase, DC systems are in demand and the study on AC/DC Hybrid system is ongoing. The current AC distribution system is characterized by a passive, unidirectional flow of power, which limits power control and causes power loss in AC/DC conversion for DC demands. The AC/DC Hybrid distribution system improves system operational efficiency by integrating DC systems into existing AC system, expanding the capacity for renewable energy integration, and reducing conversion losses from AC to DC. However, depending on the line configuration, AC/DC cables may be positioned adjacently, potentially causing electro-magnetic interference (EMI) between them. This paper proposes the best grounding methods of underground cable which is appropriate to the AC/DC Hybrid distribution system. The validation of the grounding methods of underground cable was performed by Electro-Magnetic Transients Program (EMTP) ATP-Draw.

The Transactions of The Korean Institute of Electrical EngineersVol. 74(5)
Openalex Percentile: Top 81%
Railway Systems and Energy Efficiency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Electro-Magnetic Interference on Underground Cable According to Grounding Methods in AC/DC Hybrid Distribution Networks — Chul‐Hwan Kim, Sung-Man Kang, et al. · The Transactions of The Korean Institute of Electrical Engineers (2025) | TGRS Research Map | TGRS