Stability Testing of an Air Quality Monitoring System for Particulate Matter (PM2.5 and PM10) Based on The SEN0233 Sensor

Particulate Matter (PM) is an air pollutant that has the potential to pose serious health risks to the public, including respiratory and cardiovascular diseases. This study aims to design and develop a real-time monitoring system for PM2.5 and PM10 using the SEN0233 sensor. This system is expected to be able to provide accurate data on the concentration of particles in the air. The research methodology includes selecting the right sensor, designing a NodeMCU microcontroller-based system, and testing the sensor to ensure measurement accuracy. The collected data will be stored in a database and can be accessed through a web interface, allowing users to monitor air quality directly. Initial test results show that the SEN0233 sensor is able to detect PM2.5 and PM10 concentrations well. This research contributes to the development of a more efficient and reliable monitoring system, to improve air quality and overall public health.

Authors

Institutions

Publication Details

Journal
Journal of Engineering Science and Technology Management (JES-TM)
Published
2025-03-28
DOI
https://doi.org/10.31004/jestm.v5i1.205
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability Testing of an Air Quality Monitoring System for Particulate Matter (PM2.5 and PM10) Based on The SEN0233 Sensor

Alfani Risman Nugroho, Wahyu Wijaya Widiyanto, Anshah Silmi Afifah, Putri Dwi Haryati et al.
Journal of Engineering Science and Technology Management (JES-TM)
Air Quality Monitoring and Forecasting
article

Stability Testing of an Air Quality Monitoring System for Particulate Matter (PM2.5 and PM10) Based on The SEN0233 Sensor

Alfani Risman Nugroho, Wahyu Wijaya Widiyanto, Anshah Silmi Afifah, Putri Dwi Haryati, Edo Ardiyan Syah
article en

Abstract

Particulate Matter (PM) is an air pollutant that has the potential to pose serious health risks to the public, including respiratory and cardiovascular diseases. This study aims to design and develop a real-time monitoring system for PM2.5 and PM10 using the SEN0233 sensor. This system is expected to be able to provide accurate data on the concentration of particles in the air. The research methodology includes selecting the right sensor, designing a NodeMCU microcontroller-based system, and testing the sensor to ensure measurement accuracy. The collected data will be stored in a database and can be accessed through a web interface, allowing users to monitor air quality directly. Initial test results show that the SEN0233 sensor is able to detect PM2.5 and PM10 concentrations well. This research contributes to the development of a more efficient and reliable monitoring system, to improve air quality and overall public health.

Journal of Engineering Science and Technology Management (JES-TM)Vol. 5(1)
Zhejiang Industry Polytechnic College (CN)
Openalex Percentile: Top 87%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.