Service life extension of concrete tunnels by means of impressed current cathodic protection (ICCP) – Case study: Throne tunnel (Brussels)

Impressed current cathodic protection (ICCP) was adopted as a durable repair strategy to extend the service life of a 55-year old reinforced concrete tunnel roof slab, owing to a widespread risk for damage due to reinforcement corrosion. An ICCP system with TiMMO ribbon anodes in a shotcrete overlay was designed, divided into 24 zones. An 85 m 2 test area was installed to verify the design and assess the performance during a 43-day trial period. A cathodic current density of 14 mA/m² steel was found to be sufficient to obtain an adequate protection of the steel reinforcement, demonstrated by decay measurements according to the European standard EN ISO 12696:2022.

Authors

Institutions

Publication Details

Journal
MATEC Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/matecconf/202540905004
Primary Topic
Underground infrastructure and sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Service life extension of concrete tunnels by means of impressed current cathodic protection (ICCP) – Case study: Throne tunnel (Brussels)

Mathias Maes, Bjorn Van Belleghem
MATEC Web of Conferences
Underground infrastructure and sustainability
article

Service life extension of concrete tunnels by means of impressed current cathodic protection (ICCP) – Case study: Throne tunnel (Brussels)

Mathias Maes, Bjorn Van Belleghem
article en

Abstract

Impressed current cathodic protection (ICCP) was adopted as a durable repair strategy to extend the service life of a 55-year old reinforced concrete tunnel roof slab, owing to a widespread risk for damage due to reinforcement corrosion. An ICCP system with TiMMO ribbon anodes in a shotcrete overlay was designed, divided into 24 zones. An 85 m 2 test area was installed to verify the design and assess the performance during a 43-day trial period. A cathodic current density of 14 mA/m² steel was found to be sufficient to obtain an adequate protection of the steel reinforcement, demonstrated by decay measurements according to the European standard EN ISO 12696:2022.

MATEC Web of ConferencesVol. 409
Ghent University (BE)
Openalex Percentile: Top 86%
Underground infrastructure and sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.