A soft robotic “Add-on” for colonoscopy: increasing safety and comfort through force monitoring

Colonoscopy is vital for diagnosing colorectal cancer, but limitations in instrument dexterity and sensor feedback can affect safety and patient comfort. We propose a disposable soft robotic "add-on" that attaches to existing endoscopic tools, enhancing safety without requiring custom instruments or workflow changes. The robot features soft optical sensors for 3D shape detection and force monitoring. If excessive force is detected, soft actuators redistribute pressure. A graphical interface provides real-time force data alongside the endoscope camera view. Validation experiments show accurate 3D shape reconstruction (8.51% curvature error, 9.67% orientation error) and force estimation up to 6 N with 3.38% accuracy. In-vitro tests confirm effective force redistribution, while ex-vivo tests on a bovine colon demonstrate smooth integration with minimal impact on the user learning curve. In-vivo swine studies validate safety and feasibility, confirming compatibility with existing tools and minimal disruption to clinical workflows, ensuring an efficient colonoscopy experience.

Authors

Institutions

Publication Details

Journal
npj Robotics
Published
2025-06-13
DOI
https://doi.org/10.1038/s44182-025-00028-1
Citations
3
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A soft robotic “Add-on” for colonoscopy: increasing safety and comfort through force monitoring

Sheila Russo, Max McCandless, Hiroyuki Aihara, Emma Capaldi et al.
3 citations
npj Robotics
Soft Robotics and Applications
2.02
article

A soft robotic “Add-on” for colonoscopy: increasing safety and comfort through force monitoring

Sheila Russo, Max McCandless, Hiroyuki Aihara, Emma Capaldi, Arincheyan Gerald, Johann Pang, Viola Del Bono, Casper Muter, Mark Baldiswieler
article en
3 citations

Abstract

Colonoscopy is vital for diagnosing colorectal cancer, but limitations in instrument dexterity and sensor feedback can affect safety and patient comfort. We propose a disposable soft robotic "add-on" that attaches to existing endoscopic tools, enhancing safety without requiring custom instruments or workflow changes. The robot features soft optical sensors for 3D shape detection and force monitoring. If excessive force is detected, soft actuators redistribute pressure. A graphical interface provides real-time force data alongside the endoscope camera view. Validation experiments show accurate 3D shape reconstruction (8.51% curvature error, 9.67% orientation error) and force estimation up to 6 N with 3.38% accuracy. In-vitro tests confirm effective force redistribution, while ex-vivo tests on a bovine colon demonstrate smooth integration with minimal impact on the user learning curve. In-vivo swine studies validate safety and feasibility, confirming compatibility with existing tools and minimal disruption to clinical workflows, ensuring an efficient colonoscopy experience.

npj RoboticsVol. 3(1)
Boston University (US), Brigham and Women's Hospital (US), Harvard University (US)
Brigham and Women's Hospital
Openalex Percentile: Top 14%
Soft Robotics and Applications
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A soft robotic “Add-on” for colonoscopy: increasing safety and comfort through force monitoring — Sheila Russo, Max McCandless, et al. · npj Robotics (2025) | TGRS Research Map | TGRS