A Comparative In Vitro Analysis of Attachment and Enhanced Structural Features for Molar Distalization in Clear Aligner Therapy

This study evaluated the effects of different clear aligner (CA) designs on forces and moments during maxillary second molar distalization. Four designs were tested: attachment only (group 1), neither attachment nor enhanced structure (group 2), a combination of attachment and enhanced structure (group 3), and enhanced structure only (group 4). CAs were fabricated from thermoformed polyethylene terephthalate glycol with 30 CAs per group. Forces and moments were measured using a multi-axis transducer as the molars were distally displaced by 0.25 mm. All groups experienced buccodistal and intrusive forces. Group 3 showed the highest distalizing force (Fy = 2.51 ± 0.37 N) and intrusive force (Fz = −2.04 ± 0.48 N) and also the largest rotational moment (Mz = 3.89 ± 0.71 Nmm). Groups 3 and 4 (with enhanced structures) demonstrated significant intrusive forces (p < 0.05). Most groups exhibited mesiodistal angulation, lingual inclination, and distal rotational moments. Group 2 had the lowest moment-to-force ratio (Mx/Fy = 3.27 ± 0.44 mm), indicating inefficient bodily movement. Group 3 demonstrated significantly greater moments across all axes compared to other groups. The results indicate that designs incorporating enhanced structures with attachments increase CA stiffness and applied forces/moments, enhancing distalization efficiency while minimizing vertical side effects. This suggests that, clinically, reinforced CAs can serve as a simple yet effective modification to existing protocols in Class II orthodontic cases, enabling more efficient molar distalization without requiring complete appliance redesign or additional fabrication and allowing easy adaptation to individual treatment needs.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-06-13
DOI
https://doi.org/10.3390/app15126655
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparative In Vitro Analysis of Attachment and Enhanced Structural Features for Molar Distalization in Clear Aligner Therapy

Yong‐Il Kim, Seong-Sik Kim, Sung‐Hun Kim, Youn-Kyung Choi et al.
3 links
Applied Sciences
Orthodontics and Dentofacial Orthopedics
article

A Comparative In Vitro Analysis of Attachment and Enhanced Structural Features for Molar Distalization in Clear Aligner Therapy

Yong‐Il Kim, Seong-Sik Kim, Sung‐Hun Kim, Youn-Kyung Choi, Soo-Byung Park, Min-Jeong Jee
article en

Abstract

This study evaluated the effects of different clear aligner (CA) designs on forces and moments during maxillary second molar distalization. Four designs were tested: attachment only (group 1), neither attachment nor enhanced structure (group 2), a combination of attachment and enhanced structure (group 3), and enhanced structure only (group 4). CAs were fabricated from thermoformed polyethylene terephthalate glycol with 30 CAs per group. Forces and moments were measured using a multi-axis transducer as the molars were distally displaced by 0.25 mm. All groups experienced buccodistal and intrusive forces. Group 3 showed the highest distalizing force (Fy = 2.51 ± 0.37 N) and intrusive force (Fz = −2.04 ± 0.48 N) and also the largest rotational moment (Mz = 3.89 ± 0.71 Nmm). Groups 3 and 4 (with enhanced structures) demonstrated significant intrusive forces (p < 0.05). Most groups exhibited mesiodistal angulation, lingual inclination, and distal rotational moments. Group 2 had the lowest moment-to-force ratio (Mx/Fy = 3.27 ± 0.44 mm), indicating inefficient bodily movement. Group 3 demonstrated significantly greater moments across all axes compared to other groups. The results indicate that designs incorporating enhanced structures with attachments increase CA stiffness and applied forces/moments, enhancing distalization efficiency while minimizing vertical side effects. This suggests that, clinically, reinforced CAs can serve as a simple yet effective modification to existing protocols in Class II orthodontic cases, enabling more efficient molar distalization without requiring complete appliance redesign or additional fabrication and allowing easy adaptation to individual treatment needs.

Applied SciencesVol. 15(12)
Pusan National University Dental Hospital (KR), Pusan National University (KR)
Openalex Percentile: Top 86%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines