The Influence of pH on the Catalytic Capacity of Levodopa in the Electroreduction Processes of Zn2+ Ions

The aim of the study was to investigate the influence of L-DOPA-the gold standard in the treatment of Parkinson's disease symptoms-on the electroreduction kinetics of Zn<sup>2+</sup> ions. It was demonstrated that this effect depends not only on the concentration of the drug but also on the environment in which the process takes place. In the experimental part, cyclic voltammetry (CV), square wave voltammetry (SWV), direct current polarography (DC), and electrochemical impedance spectroscopy (EIS) were used. Based on the obtained results, it was determined that the analyzed electrode reaction, both in the absence and presence of L-DOPA, proceeded in two steps. The kinetic parameters of Zn<sup>2+</sup> ion electroreduction indicated its quasi-reversible nature in solutions with both pH = 2.0 and pH = 6.0. The presence of the drug in the lower pH solution resulted in a slight slowing down of the electrode process, whereas in the pH = 6.0 solution, it led to a significant acceleration. In both low and high pH solutions, the first step was slower and determined the rate of the entire electrode process.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2025-06-13
DOI
https://doi.org/10.3390/molecules30122590
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Influence of pH on the Catalytic Capacity of Levodopa in the Electroreduction Processes of Zn2+ Ions

Jolanta Nieszporek, Tomasz Pańczyk
Molecules
Electrochemical Analysis and Applications
article

The Influence of pH on the Catalytic Capacity of Levodopa in the Electroreduction Processes of Zn2+ Ions

Jolanta Nieszporek, Tomasz Pańczyk
article en

Abstract

The aim of the study was to investigate the influence of L-DOPA-the gold standard in the treatment of Parkinson's disease symptoms-on the electroreduction kinetics of Zn<sup>2+</sup> ions. It was demonstrated that this effect depends not only on the concentration of the drug but also on the environment in which the process takes place. In the experimental part, cyclic voltammetry (CV), square wave voltammetry (SWV), direct current polarography (DC), and electrochemical impedance spectroscopy (EIS) were used. Based on the obtained results, it was determined that the analyzed electrode reaction, both in the absence and presence of L-DOPA, proceeded in two steps. The kinetic parameters of Zn<sup>2+</sup> ion electroreduction indicated its quasi-reversible nature in solutions with both pH = 2.0 and pH = 6.0. The presence of the drug in the lower pH solution resulted in a slight slowing down of the electrode process, whereas in the pH = 6.0 solution, it led to a significant acceleration. In both low and high pH solutions, the first step was slower and determined the rate of the entire electrode process.

MoleculesVol. 30(12)
Maria Curie-Skłodowska University (PL), Jerzy Haber Institute of Catalysis and Surface Chemistry, Polish Academy of Sciences (PL)
Openalex Percentile: Top 87%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Influence of pH on the Catalytic Capacity of Levodopa in the Electroreduction Processes of Zn2+ Ions — Jolanta Nieszporek, Tomasz Pańczyk · Molecules (2025) | TGRS Research Map | TGRS