MINFLUX reveals nonnormal distribution of linkage errors in immunofluorescence labeling

As the localization precision of single-molecule localization microscopy (SMLM) advances, labeling uncertainty from linkage errors increasingly limits imaging accuracy. The distributions of these errors across common labeling strategies remain unclear, complicating corrections. In this study, we used MINFLUX, with a localization precision of 1-3 nm, to examine the probability distributions of linkage errors across three antibody labeling strategies: nanobody labeling, primary “Y” antibody labeling, and primary antibody with secondary antibody labeling. We found that the distribution of linkage errors for each strategy deviates from a normal distribution, exhibiting left skewness and a flattened shape. These distributions also vary in skewness and kurtosis between strategies, and the range of linkage error values partially overlaps between strategies. Simulations confirmed our experimental findings, revealing that antibody size and geometric orientation jointly influence linkage errors. Our results provide insight into the mechanisms driving linkage errors and suggest statistical approaches to enhance SMLM imaging accuracy. As single-molecule localization microscopy (SMLM) achieves higher precision, linkage errors from antibody labeling increasingly hinder imaging accuracy. Here, the authors employ MINFLUX to analyze linkage error distributions across various antibody labeling strategies, revealing deviations from normality and suggesting statistical methods to enhance SMLM accuracy, with implications for super-resolution imaging advancements.

Authors

Institutions

Publication Details

Journal
Communications Physics
Published
2025-06-13
DOI
https://doi.org/10.1038/s42005-025-02169-z
Citations
4
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
6.54

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MINFLUX reveals nonnormal distribution of linkage errors in immunofluorescence labeling

Miṅ Gu, Huihui Zou, Xinyi Fu, Qiming Zhang et al.
4 citations
Communications Physics
Advanced Fluorescence Microscopy Techniques
6.54
article

MINFLUX reveals nonnormal distribution of linkage errors in immunofluorescence labeling

Miṅ Gu, Huihui Zou, Xinyi Fu, Qiming Zhang, Longfang Yao, Changgui Gu, Jing Wang, Shu Li
article en
4 citations

Abstract

As the localization precision of single-molecule localization microscopy (SMLM) advances, labeling uncertainty from linkage errors increasingly limits imaging accuracy. The distributions of these errors across common labeling strategies remain unclear, complicating corrections. In this study, we used MINFLUX, with a localization precision of 1-3 nm, to examine the probability distributions of linkage errors across three antibody labeling strategies: nanobody labeling, primary “Y” antibody labeling, and primary antibody with secondary antibody labeling. We found that the distribution of linkage errors for each strategy deviates from a normal distribution, exhibiting left skewness and a flattened shape. These distributions also vary in skewness and kurtosis between strategies, and the range of linkage error values partially overlaps between strategies. Simulations confirmed our experimental findings, revealing that antibody size and geometric orientation jointly influence linkage errors. Our results provide insight into the mechanisms driving linkage errors and suggest statistical approaches to enhance SMLM imaging accuracy. As single-molecule localization microscopy (SMLM) achieves higher precision, linkage errors from antibody labeling increasingly hinder imaging accuracy. Here, the authors employ MINFLUX to analyze linkage error distributions across various antibody labeling strategies, revealing deviations from normality and suggesting statistical methods to enhance SMLM accuracy, with implications for super-resolution imaging advancements.

Communications PhysicsVol. 8(1)
University of Shanghai for Science and Technology (CN)
Natural Science Foundation of Shanghai, Royal College of Surgeons in Ireland, National Natural Science Foundation of China, Science and Technology Commission of Shanghai Municipality
Zero hunger
Openalex Percentile: Top 4%
Advanced Fluorescence Microscopy Techniques
6.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.