Improving Regions of Interest Multivariate Curve Resolution: Development of an Empirical Metric System through the Study of Passive Sampling Extracts of Wastewater in Antarctica

The huge potential of liquid chromatography-high-resolution mass spectrometry (LC-HRMS) still comes along with the challenges of data analysis. Regions of interest multivariate curve resolution (ROIMCR) is a valid chemometric tool when working in data-independent acquisition (DIA), since it provides a link between precursor and product ions based on chromatographic and spectral profiles. Still, the quality of the ROIMCR models should be carefully evaluated for a consequent reliable annotation of non-target chemicals. The present case study deals with the non-target analysis of extracts coming from passive samplers deployed in a wastewater treatment facility in Antarctica (Italian Research Station). The extracts, derived from polar organic chemical integrative samplers (POCIS), were analyzed by LC-DIA-HRMS/MS, resulting in a rich and complex data set. The use of a fit-for-purpose ROIMCR workflow ended in six models for a total of 770 resolved components; among them, approximately 100 compounds were tentatively identified thanks to the recently developed MSident software, including pharmaceuticals and natural substances. The chemical meaningfulness of all resolved MCR components was carefully checked and rationalized for the first time in a classification system, with 7 classes divided into 3 "goodness levels" (A, B, and C). Level A components were characterized by single chromatographic peaks and mass spectra with a reasonable appearance of precursor and product ions. Level B components presented flaws or anomalies in either the chromatographic or spectral profile, and level C components clearly showed unacceptable features. The percentage of high-quality MCR components (level A) ranged from 15 to 48%, while components of acceptable quality (levels A and B) reached percentages between 65% and 85%. Most annotated compounds were indeed associated with good-quality MCR components. The automatization of the proposed classification system may constitute a powerful additional tool to evaluate MCR models' quality and thus improve the reliability of ROIMCR results when applied to challenging case studies.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-06-13
DOI
https://doi.org/10.1021/acs.analchem.5c00777
Citations
1
Primary Topic
Metabolomics and Mass Spectrometry Studies
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Regions of Interest Multivariate Curve Resolution: Development of an Empirical Metric System through the Study of Passive Sampling Extracts of Wastewater in Antarctica

Henry MacKeown, Barbara Benedetti, Romá Tauler, Emanuele Magi et al.
1 citations
Analytical Chemistry
Metabolomics and Mass Spectrometry Studies
0.81
article

Improving Regions of Interest Multivariate Curve Resolution: Development of an Empirical Metric System through the Study of Passive Sampling Extracts of Wastewater in Antarctica

Henry MacKeown, Barbara Benedetti, Romá Tauler, Emanuele Magi, Carlos Pérez-López
article en
1 citations

Abstract

The huge potential of liquid chromatography-high-resolution mass spectrometry (LC-HRMS) still comes along with the challenges of data analysis. Regions of interest multivariate curve resolution (ROIMCR) is a valid chemometric tool when working in data-independent acquisition (DIA), since it provides a link between precursor and product ions based on chromatographic and spectral profiles. Still, the quality of the ROIMCR models should be carefully evaluated for a consequent reliable annotation of non-target chemicals. The present case study deals with the non-target analysis of extracts coming from passive samplers deployed in a wastewater treatment facility in Antarctica (Italian Research Station). The extracts, derived from polar organic chemical integrative samplers (POCIS), were analyzed by LC-DIA-HRMS/MS, resulting in a rich and complex data set. The use of a fit-for-purpose ROIMCR workflow ended in six models for a total of 770 resolved components; among them, approximately 100 compounds were tentatively identified thanks to the recently developed MSident software, including pharmaceuticals and natural substances. The chemical meaningfulness of all resolved MCR components was carefully checked and rationalized for the first time in a classification system, with 7 classes divided into 3 "goodness levels" (A, B, and C). Level A components were characterized by single chromatographic peaks and mass spectra with a reasonable appearance of precursor and product ions. Level B components presented flaws or anomalies in either the chromatographic or spectral profile, and level C components clearly showed unacceptable features. The percentage of high-quality MCR components (level A) ranged from 15 to 48%, while components of acceptable quality (levels A and B) reached percentages between 65% and 85%. Most annotated compounds were indeed associated with good-quality MCR components. The automatization of the proposed classification system may constitute a powerful additional tool to evaluate MCR models' quality and thus improve the reliability of ROIMCR results when applied to challenging case studies.

Analytical ChemistryVol. 97(25)
Institute of Environmental Assessment and Water Research (ES), University of Genoa (IT)
Clean water and sanitation
Openalex Percentile: Top 27%
Metabolomics and Mass Spectrometry Studies
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.