Agreement between Routine-Dose and Lower-Dose CT with and without Deep Learning–based Denoising for Active Surveillance of Solid Small Renal Masses: A Multiobserver Study

Purpose To assess the agreement between routine-dose (RD) and lower-dose (LD) contrast-enhanced CT scans, with and without Digital Imaging and Communications in Medicine-based deep learning-based denoising (DLD), in evaluating small renal masses (SRMs) during active surveillance. Materials and Methods In this retrospective study, CT scans from patients undergoing active surveillance for an SRM were included. Using a validated simulation technique, LD CT images were generated from the RD images to simulate 75% (LD75) and 90% (LD90) radiation dose reductions. Two additional LD image sets, in which the DLD was applied (LD75-DLD and LD90-DLD), were generated. Between January 2023 and June 2024, nine radiologists from three institutions independently evaluated 350 CT scans across five datasets for tumor size, tumor nearness to the collecting system (TN), and tumor shape irregularity (TSI), and interobserver reproducibility and agreement were assessed using the 95% limits of agreement with the mean (LOAM) and Gwet AC2 coefficient, respectively. Subjective and quantitative image quality assessments were also performed. Results The study sample included 70 patients (mean age, 73.2 years ± 9.2 [SD]; 48 male, 22 female). LD75 CT was found to be in agreement with RD scans for assessing SRM diameter, with a LOAM of ±2.4 mm (95% CI: 2.3, 2.6) for LD75 compared with ±2.2 mm (95% CI: 2.1, 2.4) for RD. However, a 90% dose reduction compromised reproducibility (LOAM ±3.0 mm; 95% CI: 2.8, 3.2). LD90-DLD preserved measurement reproducibility (LOAM ±2.4 mm; 95% CI: 2.3, 2.6). Observer agreement was comparable between TN and TSI assessments across all image sets, with no statistically significant differences identified (all comparisons <i>P</i> ≥ .35 for TN and <i>P</i> ≥ .02 for TSI; Holm-corrected significance threshold, <i>P</i> = .013). Subjective and quantitative image quality assessments confirmed that DLD effectively restored image quality at reduced dose levels: LD75-DLD had the highest overall image quality, significantly lower noise, and improved contrast-to-noise ratio compared with RD (<i>P</i> < .001). Conclusion A 75% reduction in radiation dose is feasible for SRM assessment in active surveillance using CT with a conventional iterative reconstruction technique, whereas applying DLD allows submillisievert dose reduction. <b>Keywords:</b> CT, Urinary, Kidney, Radiation Safety, Observer Performance, Technology Assessment <i>Supplemental material is available for this article.</i> © RSNA, 2025 See also commentary by Muglia in this issue.

Authors

Institutions

Publication Details

Journal
Radiology Imaging Cancer
Published
2025-06-13
DOI
https://doi.org/10.1148/rycan.240250
Citations
4
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
2.70

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Agreement between Routine-Dose and Lower-Dose CT with and without Deep Learning–based Denoising for Active Surveillance of Solid Small Renal Masses: A Multiobserver Study

Stig Müller, Ivar Mjåland Salte, Lise Medrud, Rasa Mikalone et al.
4 citations
Radiology Imaging Cancer
Advanced X-ray and CT Imaging
2.70
article

Agreement between Routine-Dose and Lower-Dose CT with and without Deep Learning–based Denoising for Active Surveillance of Solid Small Renal Masses: A Multiobserver Study

Stig Müller, Ivar Mjåland Salte, Lise Medrud, Rasa Mikalone, Anne Negård, Jens Borgbjerg, Jens Brøndum Frøkjær, Cathrine Helgestad Kristiansen, Gintare Naujokaite, Tommy Kjærgaard Nielsen, N. Larsen, Bendik Stensby Breen
article en
4 citations

Abstract

Purpose To assess the agreement between routine-dose (RD) and lower-dose (LD) contrast-enhanced CT scans, with and without Digital Imaging and Communications in Medicine-based deep learning-based denoising (DLD), in evaluating small renal masses (SRMs) during active surveillance. Materials and Methods In this retrospective study, CT scans from patients undergoing active surveillance for an SRM were included. Using a validated simulation technique, LD CT images were generated from the RD images to simulate 75% (LD75) and 90% (LD90) radiation dose reductions. Two additional LD image sets, in which the DLD was applied (LD75-DLD and LD90-DLD), were generated. Between January 2023 and June 2024, nine radiologists from three institutions independently evaluated 350 CT scans across five datasets for tumor size, tumor nearness to the collecting system (TN), and tumor shape irregularity (TSI), and interobserver reproducibility and agreement were assessed using the 95% limits of agreement with the mean (LOAM) and Gwet AC2 coefficient, respectively. Subjective and quantitative image quality assessments were also performed. Results The study sample included 70 patients (mean age, 73.2 years ± 9.2 [SD]; 48 male, 22 female). LD75 CT was found to be in agreement with RD scans for assessing SRM diameter, with a LOAM of ±2.4 mm (95% CI: 2.3, 2.6) for LD75 compared with ±2.2 mm (95% CI: 2.1, 2.4) for RD. However, a 90% dose reduction compromised reproducibility (LOAM ±3.0 mm; 95% CI: 2.8, 3.2). LD90-DLD preserved measurement reproducibility (LOAM ±2.4 mm; 95% CI: 2.3, 2.6). Observer agreement was comparable between TN and TSI assessments across all image sets, with no statistically significant differences identified (all comparisons <i>P</i> ≥ .35 for TN and <i>P</i> ≥ .02 for TSI; Holm-corrected significance threshold, <i>P</i> = .013). Subjective and quantitative image quality assessments confirmed that DLD effectively restored image quality at reduced dose levels: LD75-DLD had the highest overall image quality, significantly lower noise, and improved contrast-to-noise ratio compared with RD (<i>P</i> < .001). Conclusion A 75% reduction in radiation dose is feasible for SRM assessment in active surveillance using CT with a conventional iterative reconstruction technique, whereas applying DLD allows submillisievert dose reduction. <b>Keywords:</b> CT, Urinary, Kidney, Radiation Safety, Observer Performance, Technology Assessment <i>Supplemental material is available for this article.</i> © RSNA, 2025 See also commentary by Muglia in this issue.

Radiology Imaging CancerVol. 7(4)
Aalborg University Hospital (DK), Akershus University Hospital (NO), Aarhus University Hospital (DK)
Akershus Universitetssykehus
Openalex Percentile: Top 10%
Advanced X-ray and CT Imaging
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.