LC-MS/MS Method for Identification & Quantification of Varenicline Nitroso Impurities (NDSRi) by Utilizing QTRAP 4500 Mass Detector from Formulation Dosage Form

Background: Nitrosamines are known carcinogens. Regulatory bodies like the FDA and EMA have set strict limits for their presence in pharmaceuticals. Monitoring and controlling nitrosamine level ensures product quality and purity. Therefore, suitable analytical tools are essential for estimating nitrosamine impurities, ensuring safety, quality, and regulatory compliance. Purpose of study: The research aimed to develop and validate an LC-MS/MS method for the estimation of three potential nitrosamine impurities related to Varenicline, namely nitroso-Varenicline impurity, nitrosamine impurity A, and nitrosamine impurity B, and its application to pharmaceutical dosage forms. Method: The optimized method includes LC-MS/MS coupled with a Sciex QTRAP 4500 mass detector. Analytical separation was achieved with a biphenyl column (150 x 4.6 mm, 2.6 µm), employing a gradient system with a flow rate of 0.4 mL/min and an injection volume of 20 µL. The auto-sampler and column oven temperatures were maintained at 15°C and 30°C, respectively. Samples were introduced to the mass spectrometer via electrospray ionization using the following conditions: Scan type: MRM; polarity: positive; ion source: ESI; curtain gas: 40 psi; probe temperature: 500°C; GS: 30 psi; GS2: 30 psi; ion spray voltage: 5500 V. Results: The developed method was validated and observed to be selective, specific, precise, linear, accurate, and highly sensitive, as the observed LOQ level for Nitroso-Varenicline impurity and Nitrosamine impurity B is 0.5 ppm, whereas for Nitrosamine impurity A, it is 0.4 ppm. The method was applied to multiple batches of Varenicline tablets. Conclusion: The newly developed and validated LC-MS/MS method is an essential tool for analyzing nitrosamine impurities in pharmaceuticals, meeting regulatory requirements and industry standards. It is suitable for its intended purpose and serves as a robust tool for estimating carcinogenic impurities in pharmaceutical drug substances and products during the drug development process and quality control analysis.

Authors

Institutions

Publication Details

Journal
International Journal of Pharmaceutical Sciences and Nanotechnology
Published
2025-04-15
DOI
https://doi.org/10.37285/ijpsn.2025.18.2.7
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LC-MS/MS Method for Identification & Quantification of Varenicline Nitroso Impurities (NDSRi) by Utilizing QTRAP 4500 Mass Detector from Formulation Dosage Form

Jayesh Pandharinath Tamhanekar, Abhinav Tiwari, Sushama Raju Ambadekar, Vijay Arjun Bagul
International Journal of Pharmaceutical Sciences and Nanotechnology
Analytical Methods in Pharmaceuticals
article

LC-MS/MS Method for Identification & Quantification of Varenicline Nitroso Impurities (NDSRi) by Utilizing QTRAP 4500 Mass Detector from Formulation Dosage Form

Jayesh Pandharinath Tamhanekar, Abhinav Tiwari, Sushama Raju Ambadekar, Vijay Arjun Bagul
article en

Abstract

Background: Nitrosamines are known carcinogens. Regulatory bodies like the FDA and EMA have set strict limits for their presence in pharmaceuticals. Monitoring and controlling nitrosamine level ensures product quality and purity. Therefore, suitable analytical tools are essential for estimating nitrosamine impurities, ensuring safety, quality, and regulatory compliance. Purpose of study: The research aimed to develop and validate an LC-MS/MS method for the estimation of three potential nitrosamine impurities related to Varenicline, namely nitroso-Varenicline impurity, nitrosamine impurity A, and nitrosamine impurity B, and its application to pharmaceutical dosage forms. Method: The optimized method includes LC-MS/MS coupled with a Sciex QTRAP 4500 mass detector. Analytical separation was achieved with a biphenyl column (150 x 4.6 mm, 2.6 µm), employing a gradient system with a flow rate of 0.4 mL/min and an injection volume of 20 µL. The auto-sampler and column oven temperatures were maintained at 15°C and 30°C, respectively. Samples were introduced to the mass spectrometer via electrospray ionization using the following conditions: Scan type: MRM; polarity: positive; ion source: ESI; curtain gas: 40 psi; probe temperature: 500°C; GS: 30 psi; GS2: 30 psi; ion spray voltage: 5500 V. Results: The developed method was validated and observed to be selective, specific, precise, linear, accurate, and highly sensitive, as the observed LOQ level for Nitroso-Varenicline impurity and Nitrosamine impurity B is 0.5 ppm, whereas for Nitrosamine impurity A, it is 0.4 ppm. The method was applied to multiple batches of Varenicline tablets. Conclusion: The newly developed and validated LC-MS/MS method is an essential tool for analyzing nitrosamine impurities in pharmaceuticals, meeting regulatory requirements and industry standards. It is suitable for its intended purpose and serves as a robust tool for estimating carcinogenic impurities in pharmaceutical drug substances and products during the drug development process and quality control analysis.

International Journal of Pharmaceutical Sciences and NanotechnologyVol. 18(2)
Homi Bhabha National Institute (IN)
Openalex Percentile: Top 85%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.