Active Learning Improves Ionization Efficiency Predictions and Quantification in Nontargeted LC/HRMS

Liquid chromatography electrospray ionization high-resolution mass spectrometry (LC/ESI/HRMS) is frequently employed in nontargeted screening (NTS) due to its high selectivity and sensitivity. However, data interpretation is challenging since the number of chemical standards available for quantification is limited and the response of the chemicals vastly differs depending on their structure and analysis conditions. Therefore, machine learning (ML) models have been utilized to predict ionization efficiency (<i>IE</i>) and enable the quantification of detected chemicals. It has been observed that the error in the predictions is high for chemicals structurally different from the training data. To enlarge the training set and to accurately predict the IE given a limited labeling budget, active learning (AL) is proposed to acquire informative data points from the targeted chemical space. In the current study, four AL approaches (clustering-based, uncertainty-based, mix, and anticlustering) and a baseline approach (random) were evaluated for <i>IE</i> prediction. The RMSE of the <i>IE</i> in the targeted space dropped significantly (up to 0.3 log units) after a single AL iteration, highlighting the necessity of chemical space exploration before ML model execution. Clustering-based AL reduced the RMSE least, while the uncertainty-based AL was inefficient if ten or more chemicals were sampled in one iteration, thereby reducing its practicality. Finally, expanding the chemical space improved the quantification accuracy from a fold error of 4.13× to 2.94× for five natural products in <i>Alpinia officinarum</i>, thereby demonstrating the need for updating the chemical space coverage of the training set.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-06-13
DOI
https://doi.org/10.1021/acs.analchem.5c00816
Citations
1
Primary Topic
Metabolomics and Mass Spectrometry Studies
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Active Learning Improves Ionization Efficiency Predictions and Quantification in Nontargeted LC/HRMS

Nahid Amini, Anneli Kruve, Wei‐Chieh Wang, Carolin Huber et al.
1 citations
Analytical Chemistry
Metabolomics and Mass Spectrometry Studies
0.81
article

Active Learning Improves Ionization Efficiency Predictions and Quantification in Nontargeted LC/HRMS

Nahid Amini, Anneli Kruve, Wei‐Chieh Wang, Carolin Huber, Meelis Kull
article en
1 citations

Abstract

Liquid chromatography electrospray ionization high-resolution mass spectrometry (LC/ESI/HRMS) is frequently employed in nontargeted screening (NTS) due to its high selectivity and sensitivity. However, data interpretation is challenging since the number of chemical standards available for quantification is limited and the response of the chemicals vastly differs depending on their structure and analysis conditions. Therefore, machine learning (ML) models have been utilized to predict ionization efficiency (<i>IE</i>) and enable the quantification of detected chemicals. It has been observed that the error in the predictions is high for chemicals structurally different from the training data. To enlarge the training set and to accurately predict the IE given a limited labeling budget, active learning (AL) is proposed to acquire informative data points from the targeted chemical space. In the current study, four AL approaches (clustering-based, uncertainty-based, mix, and anticlustering) and a baseline approach (random) were evaluated for <i>IE</i> prediction. The RMSE of the <i>IE</i> in the targeted space dropped significantly (up to 0.3 log units) after a single AL iteration, highlighting the necessity of chemical space exploration before ML model execution. Clustering-based AL reduced the RMSE least, while the uncertainty-based AL was inefficient if ten or more chemicals were sampled in one iteration, thereby reducing its practicality. Finally, expanding the chemical space improved the quantification accuracy from a fold error of 4.13× to 2.94× for five natural products in <i>Alpinia officinarum</i>, thereby demonstrating the need for updating the chemical space coverage of the training set.

Analytical ChemistryVol. 97(25)
Helmholtz Centre for Environmental Research (DE), Stockholm University (SE), University of Tartu (EE)
Vetenskapsrådet, Stockholms Universitet
Openalex Percentile: Top 27%
Metabolomics and Mass Spectrometry Studies
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.