A Dual-Focus Cloud–Edge Collaborative Framework in Multitask Hemodynamic Parameter Cross-Scale Analysis: The Equilibrium of Clinical Performance and Efficiency

The precise monitoring of hemodynamic parameters is crucial for cardiovascular health assessment and disease prevention. However, current non-invasive hemodynamic monitoring technologies fail to balance performance and efficiency. To overcome these challenges, this study introduces a dual-focus multi-task fusion framework built on a Sparse Multi-gate Mixture-of-Experts Network (SM2oE) and multi-view photoplethysmography (PPG) for the accurate estimation of non-invasive hemodynamic parameters. This framework integrates a multi-scale fusion architecture with a hybrid attention mechanism and incorporates an Uncertainty Regression Loss function (UR-Loss) to enhance inter-task information fusion and overall model performance. Through structured pruning and bidirectional knowledge distillation, the framework effectively reduces computational costs and ensures model efficiency. Cross-database evaluation demonstrates that the proposed method achieves blood pressure estimation performance falling within the numerical thresholds specified by IEEE, BHS, and AAMI guidelines. Under a lightweight strategy, the LSM2oE exhibits significant clinical application potential, with mean absolute errors for systolic blood pressure, mean arterial pressure, diastolic blood pressure, and heart rate being 4.02 mmHg, 2.99 mmHg, 3.00 mmHg, and 2.40 bpm, respectively. The parameter counts and FLOPs are 1.26 M and 0.15 Gmac, respectively, surpassing existing baseline models with only 4.0% of the parameter volume of the teacher model. Additionally, leveraging a cloud-edge collaboration framework, we achieved hemodynamic assessment across multiple IoMT devices via a local area network and the RV1126 platform. The system demonstrates cross-scale analysis capability and real-time parameter estimation performance in IoMT environments, showcasing extensive application potential.

Authors

Institutions

Publication Details

Journal
IEEE Internet of Things Journal
Published
2025-06-13
DOI
https://doi.org/10.1109/jiot.2025.3579524
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Dual-Focus Cloud–Edge Collaborative Framework in Multitask Hemodynamic Parameter Cross-Scale Analysis: The Equilibrium of Clinical Performance and Efficiency

Wei Xiang, Shuaicong Hu, Cuiwei Yang, Yanan Wang et al.
IEEE Internet of Things Journal
Hemodynamic Monitoring and Therapy
article

A Dual-Focus Cloud–Edge Collaborative Framework in Multitask Hemodynamic Parameter Cross-Scale Analysis: The Equilibrium of Clinical Performance and Efficiency

Wei Xiang, Shuaicong Hu, Cuiwei Yang, Yanan Wang, Jian Liu
article en

Abstract

The precise monitoring of hemodynamic parameters is crucial for cardiovascular health assessment and disease prevention. However, current non-invasive hemodynamic monitoring technologies fail to balance performance and efficiency. To overcome these challenges, this study introduces a dual-focus multi-task fusion framework built on a Sparse Multi-gate Mixture-of-Experts Network (SM2oE) and multi-view photoplethysmography (PPG) for the accurate estimation of non-invasive hemodynamic parameters. This framework integrates a multi-scale fusion architecture with a hybrid attention mechanism and incorporates an Uncertainty Regression Loss function (UR-Loss) to enhance inter-task information fusion and overall model performance. Through structured pruning and bidirectional knowledge distillation, the framework effectively reduces computational costs and ensures model efficiency. Cross-database evaluation demonstrates that the proposed method achieves blood pressure estimation performance falling within the numerical thresholds specified by IEEE, BHS, and AAMI guidelines. Under a lightweight strategy, the LSM2oE exhibits significant clinical application potential, with mean absolute errors for systolic blood pressure, mean arterial pressure, diastolic blood pressure, and heart rate being 4.02 mmHg, 2.99 mmHg, 3.00 mmHg, and 2.40 bpm, respectively. The parameter counts and FLOPs are 1.26 M and 0.15 Gmac, respectively, surpassing existing baseline models with only 4.0% of the parameter volume of the teacher model. Additionally, leveraging a cloud-edge collaboration framework, we achieved hemodynamic assessment across multiple IoMT devices via a local area network and the RV1126 platform. The system demonstrates cross-scale analysis capability and real-time parameter estimation performance in IoMT environments, showcasing extensive application potential.

IEEE Internet of Things JournalVol. 12(17)
Fudan University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 77%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.