Analysis of Airflow Distribution and Upper Surface Heavily Polluted Areas on Series Double-Column Isolating Switch Insulators for EMUs

When the heavily polluted zones (HPZs) on the leeward side of the high voltage isolating switch insulators (HVISIs) on the high-speed train roof increases, the flashover voltage decreases, thereby increasing the risk of interrupting the train’s power supply. This paper proposes proportion of heavily polluted areas (PHPA) calculation method based on the circumferential angle α, which corresponds to the lowest pressure points, and the circumferential angle β, which corresponds to the boundary layer separation points. The results show that the PHPA for both the upstream insulator (UI) and the downstream insulator (DI) is less than 29.2%. The HPZs on the leeward side of the UI are symmetrically distributed along the flow direction centerline. In contrast, the leeward HPZs of the DI, affected by the wake of the UI, are asymmetrical. The PHPA derived from α is greater than the experimental result, while that obtained from β is smaller than the experimental result. The relative difference between the average value derived from α and β is less than 13.9% compared to the experimental result, the universality of the proposed calculation method was verified with other series double-column insulators. The proposed calculation method can effectively reduce the experimental workload when measuring HPZs, and it can also provide a reference for the preliminary work on structural optimization design for new anti-pollution insulators.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2025-06-13
DOI
https://doi.org/10.1109/tdei.2025.3579465
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Airflow Distribution and Upper Surface Heavily Polluted Areas on Series Double-Column Isolating Switch Insulators for EMUs

Liang Mao, Youqiang Wu, Jianqiao Ma
IEEE Transactions on Dielectrics and Electrical Insulation
Engineering Applied Research
article

Analysis of Airflow Distribution and Upper Surface Heavily Polluted Areas on Series Double-Column Isolating Switch Insulators for EMUs

Liang Mao, Youqiang Wu, Jianqiao Ma
article en

Abstract

When the heavily polluted zones (HPZs) on the leeward side of the high voltage isolating switch insulators (HVISIs) on the high-speed train roof increases, the flashover voltage decreases, thereby increasing the risk of interrupting the train’s power supply. This paper proposes proportion of heavily polluted areas (PHPA) calculation method based on the circumferential angle α, which corresponds to the lowest pressure points, and the circumferential angle β, which corresponds to the boundary layer separation points. The results show that the PHPA for both the upstream insulator (UI) and the downstream insulator (DI) is less than 29.2%. The HPZs on the leeward side of the UI are symmetrically distributed along the flow direction centerline. In contrast, the leeward HPZs of the DI, affected by the wake of the UI, are asymmetrical. The PHPA derived from α is greater than the experimental result, while that obtained from β is smaller than the experimental result. The relative difference between the average value derived from α and β is less than 13.9% compared to the experimental result, the universality of the proposed calculation method was verified with other series double-column insulators. The proposed calculation method can effectively reduce the experimental workload when measuring HPZs, and it can also provide a reference for the preliminary work on structural optimization design for new anti-pollution insulators.

IEEE Transactions on Dielectrics and Electrical InsulationVol. 33(1)
Lanzhou Jiaotong University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 86%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Airflow Distribution and Upper Surface Heavily Polluted Areas on Series Double-Column Isolating Switch Insulators for EMUs — Liang Mao, Youqiang Wu, et al. · IEEE Transactions on Dielectrics and Electrical Insulation (2025) | TGRS Research Map | TGRS