DPOAE Responses in Humans and Ear Models: Can a Single-Loudspeaker Approach Match the Two-Loudspeaker Technique?
When a dual-tone frequency stimulus (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>) is presented to the ear, the cochlea responds by generating a tone at 2<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> − <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, known as the distortion product otoacoustic emission (DPOAE), useful for assessing cochlear health. Typically, to measure emissions from one ear, tones at <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> are generated by two separate loudspeakers and delivered through tubing to a single earphone in most clinical DPOAE devices. Using a single loudspeaker, however, introduces cubic intermodulation distortion (IMD) at 2<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>−<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, which interferes with the DPOAE signal, making accurate measurements difficult. In this study, to enable DPOAE measurement using only one loudspeaker, we designed a three-tone stimulus. The third tone was adjusted in phase and amplitude to destructively interfere with the IMD at 2<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> − <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, effectively canceling it. Using an IEC 60318–4 ear simulator, we optimized the third tone parameters and then measured DPOAEs with single- and two-loudspeaker setups. DPOAEs from 54 human ears were measured at frequencies from 1–8 kHz using an ER-10B+ DPOAE microphone system, with an <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>/<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">f</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> ratio of 1.22 and stimulus levels of 65/55 dB SPL (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>/<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>). Bland–Altman analysis, with limits of agreement (LoA), was performed to assess whether the method sufficiently agreed with the standard DPOAE technique. Additionally, 10 silicone ear models, created from 3D scans of real human outer ears, were used to evaluate residual IMD that cannot be measured in humans due to the presence of DPOAEs. These models accounted for the anatomical effects of the ear canal shape, providing an objective, realistic assessment of cancellation performance.
Authors
- Irwansyah Irwansyah
- Seiji Nakagawa (ORCID: https://orcid.org/0000-0002-9957-325X)
- Sho Otsuka (ORCID: https://orcid.org/0000-0003-1179-0987)
Institutions
- Chiba University (JP)
Publication Details
- Journal
- IEEE Access
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1109/access.2025.3579475
- Citations
- 2
- Primary Topic
- Speech and Audio Processing
- Type
- article
- Field-Weighted Citation Impact
- 2.97
Funders
- Japan Society for the Promotion of Science