Analysis of structural failure of glass roofs of the contemporary art museum in Wrocław

Contemporary glass structures in public buildings combine aesthetics with functionality, allowing the design of spacious, glazed spaces. This article focuses on the challenges associated with the design and construction of aluminium-glass structural roofs, analysing the case of roof failure in the courtyard of the Museum of Contemporary Art in Wrocław. Key causes of failure include material selection errors, misinterpretation of loads, and water drainage and sealing imperfections. The analysis highlights the need to consider the specific properties of glass as a building material, perform precise strength calculations, and pay close attention to the assembly details. The case study also reveals the need for further research on the interaction between glass and other materials, as well as the long-term durability of such structures. The conclusions drawn from the analysis emphasise the importance of high-quality design, thorough construction oversight, and regular maintenance, all of which contribute to increased safety and longevity of glass roofs in the future.

Authors

Institutions

Publication Details

Journal
Case Studies in Construction Materials
Published
2025-06-13
DOI
https://doi.org/10.1016/j.cscm.2025.e04872
Primary Topic
Structural Analysis of Composite Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of structural failure of glass roofs of the contemporary art museum in Wrocław

Grzegorz Dmochowski, Jerzy Szołomicki, Jan Gierczak
Case Studies in Construction Materials
Structural Analysis of Composite Materials
article

Analysis of structural failure of glass roofs of the contemporary art museum in Wrocław

Grzegorz Dmochowski, Jerzy Szołomicki, Jan Gierczak
article en

Abstract

Contemporary glass structures in public buildings combine aesthetics with functionality, allowing the design of spacious, glazed spaces. This article focuses on the challenges associated with the design and construction of aluminium-glass structural roofs, analysing the case of roof failure in the courtyard of the Museum of Contemporary Art in Wrocław. Key causes of failure include material selection errors, misinterpretation of loads, and water drainage and sealing imperfections. The analysis highlights the need to consider the specific properties of glass as a building material, perform precise strength calculations, and pay close attention to the assembly details. The case study also reveals the need for further research on the interaction between glass and other materials, as well as the long-term durability of such structures. The conclusions drawn from the analysis emphasise the importance of high-quality design, thorough construction oversight, and regular maintenance, all of which contribute to increased safety and longevity of glass roofs in the future.

Case Studies in Construction MaterialsVol. 23
Wrocław University of Science and Technology (PL), AGH University of Krakow (PL)
Sustainable cities and communities
Openalex Percentile: Top 87%
Structural Analysis of Composite Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of structural failure of glass roofs of the contemporary art museum in Wrocław — Grzegorz Dmochowski, Jerzy Szołomicki, et al. · Case Studies in Construction Materials (2025) | TGRS Research Map | TGRS